280 tMo.S.
Timeout Selection
Selects which display is switched off when Display Timout expires
Display 1
disp .1
Display 2 (Default)
disp .2
Display 1 and 2
dsp .1.2
Display 1, 2 and led
d.1.2.Ld.
281 u.M.P.c.
User Menu Pre-Programmed Cycle
Allows to modify rising/falling gradient and rentention time form the user menu, in pre-pro-
grammed cycle functioning. To access parameter modification, press SET.
Disabled (Default)
disab.
Only rising gradient
ris.Gr.
Only retention time
ma.ti.
Rising gradient and retention time
ri.G.m.t.
Only falling gradient
faL.Gr
Rising and falling gradient
ri.Fa.G.
Falling gradient and retention time
fa.G.m.t.
Rising gradient, retention time and falling gradient
r.f .G.m.t.
282 v.out
Voltage Output
Selects the voltage on the sensors power terminals and of the digital outputs (SSR).
12 volt (Default)
12 v
24 volt
24 v
283 ScL.t.
Scrolling Time
Select the duration for the visualization of the user menu data, before returning to the default
page.
3 seconds
3 s
5 seconds (Default)
s s
10 seconds
10 s
30 seconds
30 s
284 d.SP.F.
Display Special Functions
Special functions disabled
diSAb.
Shows the setpoint on display 1 and the process on display 2 (only if Par. 278
SWAP
on
c. 1 .SPv
285 nFc.L.
NFC Lock
NFC lock disabled: NFC accessible.
diSAb.
NFC lock enabled: NFC not accessible.
EnAb.
286 s.k.s.f.
Set Key Special Functions
Assign special functions to the
for 1 second. The selections
double analogue input (ATR244-23A-T e ATR244-23BC-T).
No special function linked to the
diSAb.
Start/Stop. Pressing
st./st.
Status of the controller, upon power-up, depends on parameter ini.s.
2 Threshold Command Setpoint Switch. The controller changes the regulation setpoint
2t.swi.
alternating between Set1 and Set2
3 Threshold Command Setpoint Switch. The controller changes the regulation setpoint
3t.swi.
alternating between Set1, Set2 and Set3
4 Threshold Command Setpoint Switch. The controller changes the regulation setpoint
4t.swi.
alternating between Set1, Set2, Set3 and Set4
Analogue Input 0. Set analogue input to zero (zero tare)
A.i. 0
66 - ATR244 - User manual
)
SET
button. To execute the function the button must be pressed
,
2t.swi.
3t.swi.
SET
key the controller switches from Start to Stop and viceversa.
1 MiN
5 MiN
10MiN
MAn.Sc.
,
and
are not available for versions with
4t.swi.
a.i. 0
SET
key. (Default)
1 minutes
5 minutes
10 minutes
Manual scroll
set
vi.d.2