Pos.No. Description
1
Leg
2
Latch (side door)
3
Ash house
4
Ash door compl.
5
Smoke outlet
6
Fire grate
7
Air valve
8
Bottom plate
9
Inner bottom
10
Rear plate
11
Tube frame holder
12
Air manifold
13
Front
14
Inner front
15
Side right
16
Side left
18
Ash lip
19
Top
20
Tube holder upper right
21
Tube holder upper left
22
Tube holder bottom right
23
Tube holder bottom left
24
Inspection cover
25
Side door, compl.
26
Burnplate side/door
27
Baffle plate
28
Top cover
29
Nut
30
Screw hexagon stainless
31
Screw hexagon
32
Screw collar hexagon
33
Screw hexagon
34
Screw hexagon stainless
35
Screw panh.
36
Washer blackchromating
37
Washer
38
Screw cylinder head
39
Screw allen set
40
Spring pin
41
Screw panh.
42
Screw hexagon stainless
43
Screw allen
44
Screw collar hexagon
45
Washer
46
Washer insul.
47
Gasket (side door)
48
Spring ash door
49
Gasket (front door)
50
Spring
51
Latch bolt side door
54
Hinge pin front/side door
55
Latch (ash door)
56
Handle for ash door
57
Ash pan
58
Handler for air vent
59
Latch bolt ash door
60
Sleeve ash door
61
Clip
62
Hinge pin, ash door
63
Gasket (ash door)
64
Gasket (ash house)
65
Gasket (top)
66
Insulation blanket
67
Gasket (smoke outlet)
68
Glass
69
Catch
70
Refractory brick
71
Insulation blanket top
72
Tube rear
73
Tube, middle and front
75
Heat shield bottom
77
Heat shield rear + top exit
78
Latch bolt front door
79
Glass clip
80
Gasket (door glass)
81
Gasket (top cover)
82
Latch (front door)
83
Washer
Only use replacements parts provided through your Authorized Jøtul dealer.
Alternate Floor Protection
All floor protection materials must be non-combustible ie.
metal, brick, stone, mineral fiber boards). Any combustible
material may not be used.
The easiest means of determining if a proposed alternate floor
material meets requirements listed in this manual is to follow
this procedure.
R-value = thermal resistance
k-value = thermal conductivity
C-value = thermal conductance
1. Convert the specification to R-value;
a. If R-value is given, no conversion is needed.
b. If k-value is given with a required thickness (T) in
inches: R=1/k X T.
c. If C-value is given: R=1/C.
2. Determine the R-value of the proposed alternate floor
protector.
a. Use the formula in Step 1 to convert values not
expressed as "R".
b. For multiple layers, add R-values of each layer to
determine overall R-value.
3. If the overall R-value of the system is greater than the R-
value of the specified floor protector, the alternate is
acceptable.
Example:
The specified floor protector should be 3/4" thick material with
a k-factor of 0.84. The proposed alternate is 4" brick with a C-
factor of 1.25 over 1/8" mineral board with a k-factor of 0.29.
Step A. Use formula above to convert specifications
to R-value. R=1/k X T= 1/.84 X .75 = .893
Step B. Calculate R of proposed system.
4" brick of C-1.25, therefore
R brick = 1/C = 1/1.25 = 0.80.
1/8" mineral board of k = 0.29 therefore
R mineral board = 1/.29 X 0.125 = 0.431
Total R = R brick + R mineral board=
0.8 + 0.431=1.231
Step C. Compare proposed system R = 1.231 to specified R of
0.893. Since R is greater than required, the system is acceptable.
Definitions:
Thermal conductance =
C =
Btu
=
2
(hr)(ft
)(F)
Thermal conductivity =
k =
Btu
=
W
(hr)(ft
2
)(F)
(m
2
Thermal resistance =
R =
Btu
=
(hr)(ft
2
)(F)
For the Jøtul F 600 woodstove requires floor protection with a
minimum insulating r value of 0.5.
Alcoves require an r value of 1.6.
USA/CANADA
W
2
(m
)(K)
=
(Btu)
)(K)
(hr)(ft)(F)
(m
2
)(K)
=
(Btu)(inch)
W
(hr)(ft
2
)(F)
19