Maintenance
1. Handle
2. Protective cap
3. Groove blade
4. Adjustment wheel, groove depth
CAUTION!
In order to be able to ensure a precise, high-quality joint, the groove blade (3) must be replaced
when it is time to do so. This also reduces the danger of injury arising from a blunt groove blade (3).
CAUTION!
When handling the groove blade (3), the protective cap (2) must be fitted.
5. Replacement protective cap
6. Blade holder
7. Clamping screw
8. 2 mm hexagon wrench key
A protective cap (2) that has
been lost or which exhibits great
wear must be replaced with one
of the two replacement protec-
tive caps (5).
The replacement caps are also
available as spare parts.
CAUTION!
If not used, the groove blade (3)
must always be secured with the
protective cap (2) because of the
danger of injury.
To replace the blade, the blade
holder (6) must be extended out
to the stop. To accomplish this,
the adjustment wheel (4) must
be rotated counterclockwise (+).
This setting exposes the clamp-
ing screw (7). Then loosen the
clamping screw (7) with a ¼
revolution and remove the groove
blade (3). Insert new groove
blade (3), align flat polish sec-
tion flush with the screw axis and
screw tightly with the clamping
screw (7).