22 | Français
Problem
The suction turbine will not switch on
again after the container has been
emptied.
The suction power is decreasing.
Dust is escaping during extraction
Automatic switch-off (wet extraction)
is not working.
The semi-automatic filter cleaning
function is not working.
After-Sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. You can find explosion drawings and information on
spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessor-
ies.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the nameplate
of the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: boschservicecentre@bosch.com
You can find further service addresses at:
www.bosch-pt.com/serviceaddresses
Disposal
The vacuum cleaner, its accessories and packaging should
be recycled in an environmentally friendly manner.
1 609 92A 60E | (01.10.2020)
Corrective measures
The mode selector switch (1) is set to "automatic start/stop".
– Set the mode selector switch (1) to the "extraction" symbol or switch on the
power tool plugged into the plug socket (2).
– Switch the dust extractor off and wait 5 seconds before switching it back on.
– Empty the container (7).
– Remove any blockages from the vacuum nozzle, suction tube (26), vacuum
hose (15) or main filter (20).
– Change the plastic bag (19) or dust bag.
– Make sure the filter holder (28) is engaged correctly.
– Place the top part of the dust extractor (10) on correctly and close the
catches (9).
– Change the pre-filter (22), main filter (20) or wet filter (21).
– Check that the main filter (20) has been fitted correctly.
– Change the main filter (20).
Automatic switch-off will not work in the presence of non-conductive liquids or foam-
ing.
– Check the fill level regularly.
– Empty the container (7).
Only for EU countries:
According to the European Directive 2012/19/EU on Waste
Electrical and Electronic Equipment and its implementation
into national law, vacuum cleaners that are no longer usable
must be collected separately and disposed of in an environ-
mentally friendly manner.
Français
Consignes de sécurité pour les
aspirateurs
entraîner de graves blessures.
Conservez tous les avertissements et toutes les instruc-
tions pour pouvoir s'y reporter ultérieurement.
Cet aspirateur n'est pas conçu
u
pour être utilisé par des enfants ni
par des personnes souffrant d'un
Do not dispose of the vacuum cleaner along
with household waste.
Lisez attentivement toutes les instructions
et consignes de sécurité. Le non-respect des
instructions et consignes de sécurité peut pro-
voquer un choc électrique, un incendie et/ou
Bosch Power Tools