3.2 Dose adjustment

Dose adjustment: coffee versions
The dose in the cup can be adjusted, if necessary, by turning
the screws (E).
Dose adjustment: cappuccino versions
In tall versions, adjustments are made as follows:
After removing the lid (41) and the cappuccino unit (93), loosen
the screw (F), adjust the coffee spout casing (90), then tighten
the screw (F).
In particular:
- Turn the screw (E) or the coffee spout casing (90)
counterclockwise to increase the amount in the left cup.
- Turn the screw (E) or the coffee spout casing (90) clockwise
to increase the amount in the right cup.
3.3 Special functions (where contemplated)
The special function key (25) described here below can only
be activated by an installation technician.
The key can be personalized with one of the following
functions:
- II Selection (according to the function, dispensing of a
second drink associated to a dispensing key);
- Stop (stops products from being dispensed);
- Deactivated (deactivates key);
- Hot water stop (stop water from being dispensed).
SECOND SELECTION Function
Enables the dispensing of a second type of drink associated
to the dispensing keys.
This function can be obtained only if a special key (25) is set
for the group chosen for dispensing, with the second
selection function.
At this point, if the special key is pressed and followed by one
of the dispensing keys that corresponds to the beverage and
the desired dose, the second beverage that was set on the
selected dispensing key will be dispensed.
N.B.: To cancel the second selection operation press the key
again (25).