Valve Inlet
Ferrule
Coupling
Nut
Supply
Tube
Coupling
Nut
Ferrule
Shut-Off
Valve
(If Used)
4. Supply Installation
NOTE: If the sink is not installed, install it at this time. Be sure to
follow all instructions packed with the sink.
Slide the coupling nuts and ferrules onto the supply tubes.
Secure the supply tubes and valve body inlets with coupling nuts.
Carefully insert the supply tubes into the valve body inlets and
shut-off valve outlets (if used).
5. Checkout Installation
Ensure that both faucet handles are turned off. Hot is clockwise
close and cold is counterclockwise close.
Turn on the hot and cold water supplies.
Check for leaks.
Remove the aerator by turning it counterclockwise.
Turn on the hot and cold faucet handles for one minute to flush
debris from the faucet.
Close the hot and cold water handles.
Reattach the aerator by turning it clockwise until hand tight.