11. Drain Installation
Disassemble the drain.
Apply plumbers putty to the underside of the flange and attach.
Apply thread sealant tape to the drain pipe threads. Tighten the
nut.
Connect the trapway. Wipe away excess plumbers putty.

12. Complete the Installation

NOTE: Avoid the area in front of the sensor for 2 minutes after
connections are complete. The sensor will not function correctly if it
is triggered in the first 2 minutes. Disconnect and reconnect the
power to reset the sensor.
Install the faucet trim following the directions provided.
Turn the water on to test the faucet.
Check for leaks.

Troubleshooting

Symptoms
Probable Causes
1. No water flow.
A. No batteries, or
batteries installed in
reverse.
Kohler Co.
Recommended Action
A. Check batteries and
batteries orientation.