Oras Electra 6220F Guía De Instalación Y Mantenimiento página 14

Ocultar thumbs Ver también para Electra 6220F:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
INSTALLATION AND MAINTENANCE GUIDE
General
These installation and maintenance instructions introduce the installation, servicing and use of the
touchless Oras Electra faucet. Please read the instructions carefully prior to installation and save them
for reference where servicing may be needed. If any fault or malfunction occurs in the faucet, please
seek the best possible advice at an expert HVAC store.
Versions
Oras Electra 6220F versions:
– Version with temperature adjustment handle, factory default (figure 1).
– Version for preset temperature (figure 2).
– Version for pre-mixed water (figure 3).
Changing to preset temperature version (figure 4)
– Detach parts 1, 2 and 3.
– Position the temperature adjustment handle (2) in place and adjust the temperature as desired.
– Put the plug (5) in place of the temperature adjustment handle.
Changing to pre-mixed water version (figure 5)
– Detach parts 1, 2 and 3.
– Unscrew the flexible hot water pipe (4). Note! left-hand thread.
– Screw the plug (6) in place of the pipe!
– Put the temperature adjustment handle (2) in place and turn it anti-clockwise (cold position) until the
limitation.
– Put the plug (5) in place of the temperature adjustment handle.
Installation (figure 6)
– Flush the inlet water pipes carefully prior to installation of Electra.
Connecting the mains current:
– Screw the power-source box to the wall.
– Open the power-source box and pull out the circuit card.
– Thread the electric cable through the cable gland.
– Make sure that the electric wires are not live and then attach them to the connection strip (1)
as shown in figure 10.
– The earth wire does not need to be connected and so can be cut.
– Tighten the cable gland nut (3) as shown in figure 10.
– Put the printed circuit board (2) back in place as shown in figures 10 and 11.
– Attach the sensor wire from the faucet to the power-source box connector and fix the cable gland in
place. Close the power-source box.
– Switch on the mains power and open the water inlet to the faucet.
– Check that the faucet operates faultlessly.
– Paste the instruction sticker where it will be seen beside the faucet.
NOTE!
The electrical connections on Electra basin faucets 6220G and 6220F may only be performed by a
professional electrician.
Servicing and adjustment may also be carried out by a suitably qualified person e.g. someone
who has completed the Electra Training School Program.
Limiting the temperature
Faucet version with the temperature adjustment handle (figure 7).
– Turn the limiter sleeve (3) clockwise for a lower maximum temperature.
14