ENGLISH
This instruction manual contains important information
and must be read carefully by competent persons prior
to any handling, transport, inspection or installation of
this product. Every care has been taken in the prepara-
tion of the instructions and information; however, it is
the responsibility of the installer to ensure the system
complies with relevant national and international regula-
tions, especially safety. The manufacturer, Soler & Palau
Sistemas de Ventilación S.L.U. accepts no responsibility
for breakages, accidents or any inconvenience caused by
failure to comply with the instructions contained in this
manual.
The fans referred to in this manual have been manu-
factured in accordance with rigorous quality control and
International standard ISO 9001. Once the product has
been installed, this manual to be retained by the end
user.
WARNINGS
Any work including transport, installation, inspection,
maintenance, service spares replacement, repair and
fi nal end of life disposal must be carried out by com-
petent persons and supervised by competent executive.
Fan equipment should be electrically isolated and loc-
ked out before any work started.
This fan must not be used in hazardous area.
The Installer, User is responsible for ensuring that the
fan is installed, operated and serviced by qualifi ed per-
sonnel, acting in accordance with all safety precautions
applicable and as required by law, regulations and stan-
dards in the country applicable.
Safety protective clothing, equipment, hearing protec-
tion, and tools may be required.
All fans are designed and manufactured in accordance
with EC Directive. Safety guard accessories are available
from S&P if required due to specifi c installation.
This instruction manual is subject to modifi cations due
to further technical developments of the fan described,
images and drawings may be simplifi ed representations.
Due to improvements and modifi cations the fan operated
may differ from the representations. We reserve the right
to vary the product without prior notice.
BSP fans are designed for smoke extraction and venti-
lation applications in residential buildings, commercial
buildings, industrial buildings and professional kitchens:
• Outdoor installation
• Motor ambient temperature: -20°C / +40°C
• Max. exhaust air temperature in continuous operation:
100°C
• Relative humidity: max. 95% non-condensing
• Non-potentially explosive atmosphere
• Low salinity atmosphere, free of corrosive chemical
agents
• CE Certifi cate F400 120 nº 370-CPR-1152 according to
EN12101-3 standard
If the fan is used in atmospheres with more than 95%
Relative Humidity (RH), consult the S&P Technical Ser-
vice fi rst.
Allow safe access to fan for inspection, maintenance, re-
placement of parts, cleaning / housekeeping.
The user is responsible for effective maintenance, re-
placement of parts, cleaning, especially where dust may
form inside the fan.
Do not remove safety protection guards or open access
doors when the fan is in operation.
If the fan is used to extract air from premises where a
boiler or other combustion appliance is installed, make
sure that the room has suffi cient air intakes to ensure
adequate combustion.
The following risks have been identifi ed for consideration:
• Installation: incorrect installation or function repre-
sents a risk to safety.
• Rotational speed: identifi ed on fan name plate and mo-
tor. Never exceed this speed.
• Rotation of impeller: identifi ed on fan with direction
arrows. Do not run impeller in reverse.
• Working temperature: identifi ed on fan nameplate and
motor. Never exceed this range.
• Foreign bodies: ensure no risk from debris, or material
that could be drawn into fan.
• If the fan is connected to ducts, check that they are
clean and that there are no objects or materials that
can be sucked in or blown out by the fan.
• Electrical risks: motor name plate data should never
be exceeded, effective connection to earth, and all
checked regularly every 6 months.
• Protection devices: These should always be operatio-
nal and never disconnected. However, Emergency ven-
tilation fan and motors are suitable for S1 duty cycle,
and one off emergency smoke operation no motor pro-
tection devices must stop this.
The fan motor power supply must be designed to accom-
modate any motor protection devices, where applicable, for
S1 duty cycle and these must be disabled or by-passed in
event of one off emergency smoke operation. Power supply
cables to fan motor must be suitable for temperature and
time stated when installed in potential fi re area. Power su-
pply should be via a protected source to enable fan to run
under emergency fi re smoke conditions, Direct on line.
Emergency ventilation fans, can be dual purpose, or de-
dicated Emergency operation. If fan is not operated for
long periods then fan should be run as prescribed by lo-
cal regulations, or as minimum 15 minutes each month,
to ensure safe operation.
TRANSPORT, LIFTING
Fan equipment and packaging are protected from adverse
atmosphere, especially water, sand, dust, vibration and ex-
cessive temperature. The packaging used for this fan has
been designed to support normal transporting conditions.
EN
13