fig. 3
Once the cooling unit is attached, insert the 2 red and
blue water hoses leaving the connection into the corre-
I
H
M
L
Q
R
P
O
G
fig. 4
3.2
INTERNAL CONNECTIONS
• Any intervention carried out inside the welding
machine must be performed by qualified personnel.
• Before working inside the welding machine, make sure
that the plug is disconnected from the power mains.
• After final inspection, the welding machine is con-
nected to the voltage indicated on the power supply
cable.
• To change the supply voltage, remove the right side
panel and arrange the voltage change terminal board
connections as shown in the figure 5.
B
F
sponding quick fittings G
of the unit, being espe-
cially careful to match the
A
colors, the power con-
nection O into the socket
P, the service connection
Q into the socket R, the
power cord H of the unit
N
into the socket I on the
power source, and the
service connection L into
the connector M on the
welding machine.
Remount the 2 cylinder
supports A on the panel
N of the cooling unit. (See
fig.4).
fig. 5
• The supply voltage may not be changed on single-
phase power sources.
• Do not use the welding machine without its cover or
E
side panels for obvious safety reasons, and to avoid alter-
ing the cooling conditions for internal components.
3.3 EXTERNAL CONNECTIONS
3.3.1 Connecting the mass clip.
• - Connect the earth cable terminal to the socket V of the
welding machine, and connect the earth clamp to the
workpiece.
3.3.2 Cylinder placement and connecting the gas hose
• Position the cylinder on the cylinder holder of the weld-
ing machine, using the straps provided to fasten it to the
rear panel of the machine.
• Periodically check for wear on the straps, and order
replacements if necessary.
• The cylinder must be equipped with a pressure regula-
tor complete with flow gauge.
• Only after positioning the cylinder, connect the outgoing
gas hose from the rear panel of the machine to the pres-
sure regulator.
• Adjust the gas flow to approximately 10/18
liters/minute.
3.3.3 Connecting the wire feeder
This power source accepts the wire feeders Art.1652 and
Art. 1654.
To connect the power source and wire feeder, use the
extension Art. 1182 (5 m) or Art. 1182.20 (10 m).
The performance and operating options of the wire feed-
er are described in the instructions enclosed with the wire
feeder itself.
4 DESCRIPTION OF CONTROLS
4.1 CONTROLS ON THE FRONTOF THE MACHINE.
A - Selector switch
1
8
7
6
5
B- Selector switch
2
1
Fine-tunes the welding volt-
age within the range previous-
2
ly selected via selector switch
S.
3
4
Select the ranges of welding
3
voltage.
4
9