26
UK
Control unit
Type
Power supply
N° motors
Motor power supply
Flashing light
Warning light
Accessories power supply
Safety device power supply
Radio receiver
Operating temperature
TECHNICAL SPECIFICATIONS / FUNCTIONS
• Red warning LEDs of N.C. contacts. There isn't the safety devices LED; the possible anomaly is indicated by
the writing SAF on the LCD.
• Green warning LEDs of N.A. contacts.
• Two electrical locks management.
• Safety test run before the opening and closing movement.
• Photocell 1 test run before the opening and closing movement.
• Amperometric circuit test run before the opening and closing movement.
• Stop and motion inversion for 2 seconds after intervention of the safety devices. At the next Start pulse the
motion restarts in the obstacle freeing direction.
• SEPARATE SAFETY DEVICES POWER SUPPLY Connect the safety devices that must be tested to this
clamp.
Digital programming of all functions.
• Working time adjustable independently in opening and closing for each single motor.
• Deceleration time adjustable independently in opening and closing for each single motor in the final motion
phase.
• Gate phase shift time adjustable independently in opening and closing.
• Adjustable pedestrian working time.
• Pause time adjustable and differentiated for complete or pedestrian opening.
• Thrust force adjustable on 10 levels for each motor.
• Decelerations selectable and adjustable independently on 10 levels for each motor.
• Absorption (anti-crushing) control adjustable on 100 levels for each single motor both in thrust phase and in
deceleration phase.
• Deceleration enable modes: with single or double limit switch.
• 4 possible working functions (step-by-step, step-by-step with stop, condominium or automatic, dead-man).
• Possibility of choosing the system configuration from swing gate (single or double), overhead/barrier and
sliding gate (single or double).
BA24 / AS05100
Electronic control unit for the automation of one
or two motors - 24V dc - for swinging and sliding gates,
overhead garage doors and barriers
230Vac monophase 50/60 Hz
24Vdc 10W max
24Vdc 3W max
24Vdc 8W max
including safety device power supply
24Vdc 8W max including accessories power supply
-20°C +60°C
BA24
1 or 2
24 Vdc
Plug-in