GiBiDi BA24 Instrucciones De Instalación página 43

Ocultar thumbs Ver también para BA24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
BA24
Menu
Function
E1
PHOTOCELL 1
E2
PHOTOCELL 2
E3
EDGE (SEFETY DEVICE)
TIMES MANAGEMENT
T3 ADDITIONAL TIME
Additional time at the end of the working time (with full force or during deceleration phase according to the
settings) that allows to continue the movement to close the leaf even if there is wind.
The T3 function is not active with the sliding configuration.
During the T3 time, the anti-crushing is not active, so the T3 time must start as near as possible next to the door
stroke.
The limit switch that determines T3 must not be trespassed in order to maintain the control of the limit switches in
event of motion inversion.
TIME PROGRAMMING PROCEDURE
CAUTION: start with the gate completely closed.
The times are programmed by means of successive START pulses.
To enter this procedure select the menu C21. (menu C21 blinking)
By pressing OK, the times programming procedure starts (menu C21 Y fixed) then:
1 motor configuration
• START
the leaf starts opening.
• When the leaf arrives at the desired opening position
• Counting of the pause time.
• When the desired pause time has elapsed
• When the leaf arrives at the closing position
• At this point the procedure has finished, the blinking menu C21 (without Y) reappears.
• If you want to repeat the operation press OK.
• If you want to finish the times programming operation saving the data, press ESC until the horizontal lines
appear on the display.
2 motors configuration
• START
the leaf 1 starts opening.
• After the desired opening phase shift time
• When the leaf 1 arrives at the desired opening position
• When the leaf 2 arrives at the desired opening position
• Counting of the pause time.
• When the desired pause time has elapsed
• After the desired closing phase shift time
Status
Description
Y
Photocell 1 enabled
N
Photocell 1 disabled
Y
Photocell 2 enabled
N
Photocell 2 disabled
Y
Edge enabled
N
Edge disabled
START
START
the leaf starts closing.
START
the leaf stops.
START
the leaf 2 starts opening.
START
START
START
the leaf 2 starts closing.
START
the leaf 1 starts closing.
the leaf stops.
the leaf 1 stops.
the leaf 2 stops.
43
UK

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

S05100

Tabla de contenido