Installation Of Appliance - JENN-AIR CCGP2420P Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Of Appliance

The installation of this appliance must conform with local
codes or, in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1-Latest Edition, or, in
Canada, CAN/CGA-B149 Installation Code, Latest
Edition.
This appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code
ANSI/NFPA No. 70-Latest Edition, or, in Canada, current
CSA Standard C22.1 Canadian Electrical Code, Part 1.
In The Commonwealth Of Massachusetts
This product must be installed by a licensed plumber or
gas fitter when installed within the Commonwealth of
Massachusetts.
A "T" handle type manual gas valve must be installed in
the gas supply line to this appliance.
A flexible gas connector, when used, must not exceed a
length of three (3) feet / 36 inches.
All supply piping, except as noted, should use common
National Pipe Thread (N.P.T.). For all pipe connections
use an approved pipe joint compound resistant to the
action of LP gas.
CAUTION: Warranty is void on Jenn-Air equipment
installed other than as recommended by manufacturer.
This appliance is designed for use with the appliance gas
pressure regulator supplied with this appliance. It must be
installed in the gasway ahead of the gas manifold
entrance. It is preset for use with natural gas and must be
converted for use with LP gas.
This appliance is designed to operate at a pressure of 5
inches of water column on natural gas or, if converted for
use with LP gas (propane or butane), 10 inches water
column. Make sure this appliance is supplied with and
adjusted for the type of gas for which it is designed.
This appliance was adjusted at the factory for use with
natural gas. If, at any time, this appliance is to be used
with a different type of gas, all of the conversion
adjustments must be made by a qualified service
technician before attempting to operate the cooktop on
that gas. Natural gas should be supplied to the appliance
pressure regulator at a line pressure between 6 and 14
inches of water column or, if converted for LP gas,
between 11 and 14 inches.
If the line pressure supplying the appliance pressure
regulator exceeds 14² W.C. (any gas), an external
regulator must be installed in the gas line ahead of the
appliance regulator to reduce the pressure to no more
than 14² W.C. Failure to do this can result in malfunction
and damage to the appliance.
Insure this appliance is adjusted for the type of gas
supplied to it and that the gas supply pressure to the
appliance regulator is within the proper pressure range.
Do not remove protective cap from pipe stub at manifold
entrance until ready to join gas supply piping to appliance.
The Countertop Cutout and Cabinet Front Cutout should
be prepared according to the illustration on page 1 and 2.
Install the Lower Control Panel in the bottom of the
Cabinet Cutout as shown using screws from Hardware
pack (Figure 6).
Position unit in the Countertop Cutout. Main Control Panel
should overlap top of Lower Control Panel as shown
(Figure 7).
4
FIGURE 6
FIGURE 7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ccgp2720pCcgp2820p

Tabla de contenido