Step 5: Locate the LP orifice spud packet taped to
the underside of the burner box. The spuds
have small numbers stamped on the side.
This number codes the orifice diameter and
its correct burner location. The following
illustrations show correct LP orifice spud
location for 4 burner and 6 burner models,
respectively.
Step 6: With the masking tape still in place in the
recess of the nut driver, press an LP orifice
spud into the recess so that it is snugly
captured.
Step 7: Carefully install the orifice spud in the
appropriate burner throat by turning clockwise
to tighten. Tighten to a torque of 15 to 20
inch-lbs.
Step 8: Replace cylindrical aluminum venturi tubes.
Replace burner heads and grates. Index each
grate to its burner pan.
Step 9: Save the orifices removed from the appliance
for future use.
Installation Of LP Orifice Spuds
48² MODEL
FIGURE 11
7
36² MODEL
FIGURE 12
30² MODEL
FIGURE 13