Warning Lights - GYS COMBIDUCTION AUTO 50 LG Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
Operating manual
Thermal-protection indicator (9)
CHANGING THE INDUCTOR TYPE
• To switch to the car body inductors, press and hold the glass/glove inductor button that has been plugged into the
socket (3) on the unit. Alternatively, press and hold the pneumatic foot pedal (18) while the main power button is
switched off. The COMBIDUCTION will then automatically register its presence and become fully functional.
• To be able to heat, whatever the inductor, press the illuminated main power button(2).
• Then, press the inductor button or the pneumatic foot pedal to start heating.
• To re-engage the lance, press the lance button (12).
Listen for a beep and a new display on the screen.
Press the main power button (2).
Then, press the lance button or pneumatic foot pedal to activate the heating process.
INDUCTOR PRESERVATION
The hot metal will radiate heat to the inductor at the square of the temperature to which it is heated. Thus, the inductor
is highly exposed. Once the metal has turned dark red, the temperature is below 850°C. If it turns bright red/orange,
the temperature has exceeded 1,000°C. If it turns white, the temperature has exceeded 1,200°C (see the colour chart
available below and on the website).
600 °C
To preserve the inductor and extend its working life, keep the temperature as low as possible (around 850°C) and avoid
prolonged use.
The ferrite in the inductor has a higher expansion coefficient than its mechanical support. Excessively heated the induc-
tor may lead to ferrite damage. It is up to the user to avoid excessive heating.
Therefore, the warranty does not cover inductors as they are consumables.

WARNING LIGHTS

- The LED indicator light (7) highlights if there is a fault with the inductor or power source.
- Indicator light (8) signals a flow failure in the liquid cooling system.
- The LED indicator light (9) signals that the power block has gone into thermal protection or that the coolant's upper-lim-
it temperature has been exceeded.
Once the indicator light has gone out, the product is ready for use again.
Display screen number five will show the fault code:
Default code
E - 1
Main power button (2) not pressed.
E - 2
Lance button not pressed (12).
E - 3
Press and hold buttons (5) or (11).
E - 4*
Inductor current is too high or not compatible.
E - 5*
Inductor current is too low
E - 6
Flow rate is too high >6 l/min
E - 7
Flow rate is too low <4 l/min
E - 8*
Internal fault
Mains voltage fault
E - 9
- - -
Over-voltage fault
*In the case of faults E-4, E-5 and E-8, restart the unit to reset the fault.
28
Translation of the original
instructions
This warning light lights up to indicate that the product has gone into thermal
protection due to overheating. As long as this warning light remains on, the
product is inoperative. It switches off when the product has sufficiently cooled
down. Only then is it possible to resume heating.
900 °C
COMBIDUCTION AUTO 50 LG
Cause
Short-circuited or mechanically blocked.
Short-circuited or mechanically blocked.
Short-circuited or mechanically blocked.
Defective lance or short-circuited inductor.
Poorly screwed-in inductor or defective lance.
Hole in hose or no inductor.
Pinched or clogged hose, pump does not work.
Control panel disconnected.
The mains voltage is too low at under 165 V.
Mains voltage above 300 V.
1,300 °C