Descargar Imprimir esta página

Hansa HANSAMIX E Serie Instrucciones De Montaje página 14

Publicidad

GB
Malfunction/fault
No water is fl owing
Sensor is fl ashing
Water fl ows continuously
Tap switches independently
Insuffi cient water fl ow
Flashing when water is fl owing
Tap is dripping
Incorrect water temperature
Electronic does not react
Settings:
Set water running time (normal function) (page 18)
The water running time can be set individually
(running time approx. 1 - 10 s)
Short Off (page 19)
Temporary interruption of the water fl ow (pause).
For undisturbed cleaning of the tap, shower, etc.
Stops automatically or at any time when button is pressed.
(after 2 min.)
12/24-hour forced fl ushing (page 20)
Flushing 12/24 hours after last use.
Continuous On: Initiate (page 21)
Permanent water fl ow. For fi lling the washbasin,
containers, etc.
Stops automatically or at any time when button is pressed.
(after max. 2 min.)
Continuous On: Programme water running time (page 22)
"Continuous On" setting (0,5-20 min)
Manual adjustment of the sensor range (page 23)
Manual sensor range adjustment to the wash-basin.
Ensures optimum comfort and prevents that the tap fi ttingruns
on its own.
Fault - Cause - Remedy
Possible cause
• Black object
• Faulty solenoid
• Faulty electronics
• Clogged/dirty sensor
• Refl ection (autom. water stop after
1 min. continuous fl ow)
• Refl ection in washbasin
• Power failure while water is fl owing
• Faulty solenoid/diaphragms
• Dirty sensor
• Refl ection in washbasin
• Insuffi cient supply pressure
• Clogged perlator
• Faulty non-return valves
• Discharged battery
• Dirty diaphragms
• Problem with water supply
• Battery discharged/faulty
• Battery incorrectly inserted
• Faulty button
• Incorrect operation
Remedy
Sensor does not recognise black
Replace solenoid
Replace electronic
Clean/strip sensor
Remove object
or "Autoset"
"Autoset" or Manual adjustment of the sensor range
Restore the power supply
Replace solenoid
Clean sensor
"Autoset" or Manual adjustment of the sensor range
Check supply line
Clean/replace perlator
Replace non-return valves
Replace battery
Clean/replace solenoid
Check water supply
Replace battery
Insert battery correctly
Replace electronics
"Autoset"

Publicidad

loading