BEFORE USE
Before each start, make sure that :
- the parts are not damaged. Replace each damaged/worn out part. Check the hose and the fireproof hood.
- the good and secured connection between the hose and the filtration unit, and between the hose and the helmet.
- the air flow is sufficient
- the air flow is constant between the filtration unit and the helmet.
- that the battery is fully charged.
Air flow test :
1
Connect the breathing hose to the filtration unit and twist it clockwise
3
Press the ON button and maintain the hose in a vertical position at
If the marble does not reach the minimum, it is necessary change/replace the battery or to change the filter and pre filter.
Is the problem persists, check page 14 for more details.
Air flow alarm test :
1
Remove the gas hose from the helmet and press the ON button.
The «Warning» LED blinks, an alarm sounds and the icon
If the alarm does not work, the respiratory system is damaged. If the device is under warranty, return it to your distributor to
diagnose the fault.
GYSMATIC 5/13 AIR XXL
to lock it.
eyes' height.
blinks on the display.
2
Insert the flowmeter at the tip of the hose.
4
The air flow is sufficient if the car if the marble reaches the
minimum flow level
2
Cover the air output with your hand and wait approximately
15 seconds.
EN
.
13