2.3.1 2-wire Heating
2.3.2 2-wire Cooling
2.3.3 3-wire Heating
2.3.4 3-wire Cooling
2.3.5 4-wire Heating and Cooling
2.3.6 5-wire Heating and Cooling
Heat relay
Note: Remove the red jumper wire between terminals Rc and Rh.
RTH1120
Heat relay
Cool relay
Heat relay
Fan relay
Cool relay
Fan relay
Heat relay
Cool relay
Fan relay
Fan relay
Cool relay
2.4 Setting J2 Jumper
The jumper specifies how the fan will operate
when it is placed in automatic mode (see sec-
tion 3.2).
Leave the jumper in this position if you
HG
have a gas or oil heating system.
Move the jumper to this position if you
HE
have an electric heating system.
2.5 Installing the Batteries
Pull out the battery cover.
Install the batteries as shown. Observe the polarity.
Reinstall the battery cover. You will hear a clicking sound.
After the batteries are installed, the thermostat performs a series of
tests for approximately 5 seconds.
Afterwards, the screen displays the actual tempera-
ture. It is normal that the displayed temperature will
be higher than the ambient temperature if you hold
the thermostat in your hands. It will display the
ambient temperature after the thermostat is
installed on the wall. By default, the setpoint is 70°F (21°C).
2.6 Completing the Installation
Once the baseplate and the batteries are installed, mount the
thermostat on the baseplate.
Secure the thermostat using the locking screw and install the
faceplate.
Apply power back to the system.
JP2 jumper
69-1876ES-1
29/11/06
2/4