noken PURE LINE 100181001_N199999253 Manual De Instrucciones página 23

Tabla de contenido

Publicidad

Problem/Fault
ENG
Lack of water supply Open the
supply valves
Water running constantly
Low flow rate
Water temperature cannot be
adjusted
Dropping Tap
Too high minimum flow rate
Failure to provide either hot or cold
water only
NOTE: The device must be turned off by disconnecting the power supply unit and removing the batteries
Possible Cause
Supply valves closed
Clogged filters on supply valves
Twisted/ Kinked Supply hoses
Clogged filter gaskets on the Control Unit
Power supply faulty
Faulty socket
Faulty power pack
Faulty control unit
Faulty/Damaged connecting
cable/connector between keyboard and
control unit
Faulty control unit
Low supply pressure
Filters of supply valves are not enough
open
Clogged filters
Twisted/ Kinked Supply hoses
Clogged filter gaskets on the Control Unit
Water supply failure
Too low temperature difference between
hot and cold water supply
Filters of supply valves are not enough
open
Clogged filters
Twisted/ Kinked Supply hoses
Clogged filter gaskets on the Control Unit
Faulty control unit
Faulty control unit
Faulty control unit
Faulty control unit
Remedy
Open the supply valves
Clean the filters
Connect hoses correctly
Clean the filters
Check the power supplier
Change the socket
Replace the power pack
Cut the power supply for 5 sec. and reconnect it, if
problem persists please contact the customer
service/replace the control unit
Check connection and if problem persists please
contact the customer service
Cut the power supply for 5 sec. and reconnect it, if
problem persists please contact the customer service/
replace the control unit
Check supply pipes
Open the filters further
Clean filters
Connect hoses correctly
Clean the filters
Check water supply/check the boiler
Check water supply/check the boiler
Open the filters further
Clean filters
Connect hoses correctly
Clean the filters
Cut the power supply for 5 sec. and reconnect it, if
problem persists please contact the customer service/
replace the control unit
Cut the power supply for 5 sec. and reconnect it, if
problem persists please contact the customer service/
replace the control unit
Cut the power supply for 5 sec. and reconnect it, if
problem persists please contact the customer service/
replace the control unit
Cut the power supply for 5 sec. and reconnect it, if
problem persists please contact the customer service/
replace the control unit
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pure line 100181000_n199999244

Tabla de contenido