SCALE REMOVAL PROGRAM – TOTAL DURATION: ABOUT 22 MINUTES.
The quantity of scale deposited depends on the hardness of the water used. The appliance will automatically
warn you by the 'calc' light coming on when you need to proceed with scale removal.
This program is only accessible when the machine requests it.
Caution! To benefit from the guarantee conditions, it is essential to perform the appliance scale removal
cycle when informed to do so. Be sure to follow the procedure closely step by step.
You can continue to use the appliance when the light is on, but you are advised to perform the program as soon
as possible.
If your appliances fitted with our Claris - Aqua Filter System F088 cartridge, please remove the cartridge
during the descaling operation.
Make certain to protect your work surface during cleaning and scale removal cycles, especially if it is
made of marble, stone or wood.
Press the 'Service'
Remove and clean the
key to start up the
drip tray.
scale removal
program. The 'calc'
and
lights will
flash.
Only use KRUPS scale removal products. You can obtain scale removal products from KRUPS Service Centres.
The manufacturer may not be held responsible for damage to the appliance through use of other products.
1 - Descaling cycle
The 'calc' light stops blinking.
The descaling cycle starts and is carried out automatically. The pump occasionally sucks up water which comes out of the
coffee nozzles and then the steam nozzle. This operation lasts approximately 10 minutes.
Put the water tank
back in place. The
light turns off and the
'calc' light stops blin-
king.
Place a receptacle with
a minimum water
capacity of 0.6 l under
the coffee outlets and
under the steam nozzle.
Press the 'Service' but-
ton after having carried
out all of these opera-
tions.
10
Empty the tank and fill
Dissolve a sachet of
it with lukewarm water
Krups scale remover
up to the 'calc' marking.
F054 (40 g).
When the cycle has
completed, the 'water
tank' and 'calc' lights
blink.
F054
± 10 mn