Energy (Refer To Fig.15); Analyzer Config, Recorder Config, And Analyzer Memory; Analyzer Configuration (Refer To Fig.16) - Amprobe DM-II PLUS Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 132
Symbol
Pt, P1, P2, P3
P12, P32
Qt, Q1, Q2, Q3
Q12, Q32
St, S1, S2, S3
S12, S32
Pft, pf1, pf2, pf3
dPft, dpf1, dpf2, dpf3

Energy (Refer to fig.15)

Displays the values of the phase and total active powers, the value of the phase and total
capacitive and inductive reactive powers, the values of the power factors and phase and total
cosϕ. Push F1 (ChgP) (for 3PH4W mode only) to display the other energy measurements:
Push F1 once to view phase 1, phase 2, and phase 3 values
Push F1 twice to view Total 3-phase values
Push F2 (Meas) to immediately start/stop a direct energy measurement. The energy counters
will increase proportionally to the active power absorbed by the load.
NOTE:The symbols "i" and "c" stand for reactive powers (Q) and energies (Er) inductive and
capacitive respectively.
Symbol
Eat, Ea1, Ea2, Ea3
Erit, Eri1, Eri2, Eri3
Erct, Erc1, Erc2, Erc3
Est, Es1, Es2, Es3

ANALyzER CoNfIg, RECoRDER CoNfIg, AND ANALyzER MEMoRy

Analyzer Configuration (Refer to fig.16)

Push MENU and select ANALYZER CONFIG using the  Up and  Down keys.
SYSTEM = Type of electrical system under test. The input connections must be the same as the
type of system selected:
SINGLE = Single Phase System
3PH3W = Three Phase System without Neutral (3 wire)
3PH4W = Three Phase System with Neutral (4 wire)
FREQUENCY = Fundamental Frequency, between 50Hz to 60Hz.
Description
Values of the active power (total, phase 1, phase 2, and phase 3
respectively)
(For 3PH3W mode only) Value of the power measured by the Watt-
meter 1-2 and 3-2 respectively
Values of the reactive power (total, phase 1, phase 2, and phase 3
respectively)
(For 3PH3W mode only) Value of the power measured by the VAR
meter Va1-2 and 3-2 respectively
Values of the apparent power (total, phase 1, phase 2, and phase 3
respectively)
(For 3PH3W mode only) Value of the power measured by the VA
meter Va1-2 and 3-2 respectively
Values of the power factors (total, phase 1, phase 2, and phase 3
respectively)
Value of the cosϕ (total, phase 1, phase 2, and phase 3 respectively)
Description
Values of the total active energy, of phase 1, phase 2,and phase 3
respectively
Values of the total inductive reactive Energy, of phase 1, phase 2,
and phase 3 respectively
Values of the total capacitive reactive Energy, of phase 1, phase
2,and phase 3 respectively
Values of the total Apparent Energy, of phase 1, phase 2, and phase
3 respectively
14

Publicidad

Tabla de contenido
loading

Tabla de contenido