GYS BATIUM 25 Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
Translation of the original instructions
8
The Batium starts the charge. It indicates the battery charge status (2), and by alternating 3s on the display
(1): the voltage in V and the current in A.
Battery charging & suggested SOS start
as the charger has detected a sulphated
battery/low voltage
Main charge.
IUoU
function
Charge supplement (equalisation)
Floating charge
Battery charging. Analyses and recovers
the battery in case of sulphation/low
voltage (if possible)
Main charge.
IUIo
function
Charge supplement (equalisation)
Charge finished
Specific to the IUoU function
Once the charge is finished, the charger is in floating mode
and compensates for the self-discharge.
Specifics of the IUIo function
When charging is complete, the BATIUM is switched off and indicates
after the end of charge, every 72h, the Batium restarts a charge cycle to compensate for the self-discharge of
the battery.
Specific to «SOS Recovery» mode
• Once the battery is desulfated, the Batium resumes a regular IUoU charge.
• If it fails to retrieve the battery, it indicates on the display
9
When the battery is charged (green light
10 Disconnect the power supply cable.
11 Disconnect the clamps / or the battery connector.
Nb: During a power failure, the Batium memorises the last configuration (except in "SOS Recovery" mode), and
takes over the last parameters.
«SOS RECOVERY» FUNCTION» (p.2)
This function is for automotive batteries (IUoU) that have been deeply discharged. It allows a stronger desulphation of
the battery.
To activate this feature, follow these steps:
1. Always disconnect the battery from the vehicle (
2. Connect the clamps of the Batium to the battery.
3. Connect the Batium to the mains then position the switch to «ON».
12
BATIUM 25/24X
Light on.
flashing light
fixed
+
fixed
flashing light
fixed
flashing light
fixed
+
fixed
flashing light
fixed
), set the switch to « OFF ».
DANGER OF OVERVOLTAGE).
Display
flashing until the battery can
be recovered (max 1h50)
Alternating display of current (Ampere)
and voltage (Volt).
Alternating display of current (Ampere)
and voltage (Volt). Duration 2 hours.
fixed.
Alternating display of current (Ampere)
and voltage (Volt).
fixed.
: it can remain connected to the battery
. If the battery stays connected
.
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Batium 24x

Tabla de contenido