Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
Translation of the original instructions
4. Select the IUoU charging curve (5).
5. Activate the function by pressing the «SOS recovery» button (3) for 5 seconds until
6. Select voltage (4) and charging rate (6).
7. Do not touch anything for a few seconds, the process begins (process identical to §8).
FORCED LOAD FUNCTION (p.2)
If the battery is heavily discharged (voltage below 2 V), the Batium will not start and this is indicated by signals:
• The display shows
• The «battery voltage», «capacity» and «charging curve» indicators are lit.
1. Press
for 5 seconds, the display shows
2. Force the charge by pressing (4), the display shows
3. The cycle starts.
The charger detects a battery with a voltage higher than 0.5 V (± 0.3 V) and starts a battery recovery cycle.
VOLTMETER FUNCTION (TEST MODE) (p.2)
This function allows the BATIUM to measure the voltage of the vehicle's battery, alternator or starter motor.
Proceed as follows:
1. Switch the Batium 25.24X on.
2. Select «test» mode (5).
3. Connect the charger to the battery.
4. Select the desired voltage (6):
To get the minimum battery voltage.
To get the battery voltage in real time.
To get the maximum battery voltage.
5. Press «Reset test» (3) to reset the voltages.
6. Press (5) to exit the «Test» mode.
PROTECTIONS
The Batium 25-24X is protected against short-circuits and polarity reversals. It has an anti-spark feature which
prevents sparks whilst connecting the device to the battery. The device will not deliver current if there is no battery
detected (no voltage in the clamps).

TROUBLESHOOTING

TROUBLESHOOTING
The unit will beep,
+
1
led
+
the display flashes :
By positioning the interrupter to «
2
ON », no indicator switches on.
During charging,
3
the display shows :
The display shows
4
BATIUM 25/24X
,
The Batium has detected a polarity
on
reversal to the clamps.
The charger has detected an abnor-
mal mains power supply voltage.
The machine is overheating.
The Batium does not detect a battery.
The clamps are incorrectly connected.
The Batium does not detect a battery. Clean the contacts or start in force
,
.
CAUSES
appears on the display.
SOLUTIONS
Connect the red clamp to the
positive terminal (+) and the black
clamp to the negative terminal (-)
of the battery.
Wait 10 seconds. If nothing is dis-
played, try another power socket.
Use the charger in a well-venti-
lated room and try again a few
minutes later.
Make sure that the clamps are
properly connected. Carry out the
connection again.
mode.
EN
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Batium 24x

Tabla de contenido