Unit Dimensions: Height 183mm Width 290mm Depth 108mm
Table 2
Power
3.5kW
4.0kW
5.0kW
5.5kW
7.0kW
7.7kW
• operating water pressure 0.2-8 BAr (3-116 psi) • Water pressure operating power switch
• standard 1/2"Ø compression inlet connection • top-left and right cable entry • Bottom-left water entry
Close cover Steps
A
kW Loaded
220V
230V
240V
3.5
3.8
4.1
4.0
4.3
4.7
5.0
5.5
6.0
5.5
6.0
6.5
7.0
7.6
8.3
7.7
8.4
9.1
B
10
Heating Setting
Recomended
Cable Size
1.5+2.0 kW
2.5/4mm
1.0+3.0 kW
2.5/4mm
2.0+3.0 kW
4/6mm
2.2+3.3 kW
4/6mm
3.0+4.0 kW
6/10mm
3.0+4.0 kW
6/10mm
Recomended
Fuse Rating
20 amps
2
20 amps
2
25 amps
2
25-32 amps
2
40 amps
2
40 amps
2
C