Dacor DOB30M977 Serie Requisitos De Instalación página 28

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation instructions
3-Wire Cable from Home Power Supply - U.S. Only
IMPORTANT: Use the 3-wire cable from home power supply where local codes permit a
3-wire connection.
A
B
C
D
E
F
A. Cable from home power supply
B. Junction box
C. Black wires (normally L1)
D. White wires (normally N-neutral)
E. green wires (normally G-ground)
F. 4-wire flexible conduit from oven
G. Red wires (normally L2)
H. UL listed wire connectors
I. UL listed or CSA approved conduit
connector
28
English
NW9000K_MOD_DOB30M977DS_DG68-00923A-01_EN+MES+CFR.indb 28
1.
Connect the 2 black wires (C) together
using a UL listed wire connector.
2.
Connect the 2 white wires (D) and
G
the green (or bare) ground wire (of
H
the oven cable) using a UL listed wire
connector.
3.
Connect the 2 red wires (G) together
using a UL listed wire connector.
I
4.
Install junction box cover.