Conversion To A Different Type Of Gas; Commissioning; Troubleshooting; Gas Fry-Top With Tap - AFG 700 Serie Instrucciones Para Instakkacion, Uso Y Manteniniento

Frytop
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 48
• Identify the specific appliance model. The model number is
detailed on the packing and on the appliance data plate.
• The appliance must be installed in a well-ventilated room.
• Do not obstruct any air vents or drains present on the ap-
pliance.
• Do not tamper with appliance components.

17 CONVERSION TO A DIFFERENT TYPE OF GAS

See Chapter " Instructions for installation "

18 COMMISSIONING

Following installation, conversion to a different type of gas or
any maintenance operations, check appliance operation.In the
event of any malfunction, consult the next Paragraph "Trou-
bleshooting".
18.1 GAS APPLIANCES
Switch on the appliance as directed in the instructions and re-
minders for use given in Chapter " INSTRUCTIONS FOR USE
" and check:
• the gas supply pressure ( see next Paragraph ).
• the correct ignition of the burners and the effectiveness of the
fumes removal system.
18.1.1
CHECKING THE GAS SUPPLY PRESSURE
• To measure the gas supply pressure use a manometer with a
minimum definition of 0.1 mbar.
• Remove the control panel.
• Remove the screw from the pressure test point PP and con-
nect the manometer to the test point.
• Make the measurement with the appliance in operation.
IMPORTANT! If the gas supply pressure is not within the limits
( Min. - Max ) indicated in Table T2 , cease operation of the
appliance and contact the gas utility company.
• Disconnect the manometer and retighten the retaining screw
on the pressure connection.
18.2 ELECTRICAL APPLIANCES
Switch on the appliance as directed in the instructions and re-
minders for use given in Chapter " INSTRUCTIONS FOR USE
" and check:
• the current values of each phase.
• the correct operation of the heating elements.

19 TROUBLESHOOTING

19.1

GAS FRY-TOP WITH TAP

The pilot burner does not light
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Igniter defective or not properly connected.
• Igniter or igniter wire defective.
Pilot burner goes out during use
Possible causes:
• Insufficient gas supply pressure.
• Defective gas tap or valve.
• Defective thermocouple or insufficient heating.
• Thermocouple incorrectly connected to gas tap or valve.
• Knob of gas tap or valve not pressed sufficiently.
36
The main burner does not light ( even though pilot is lit )
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Defective burner ( gas outlet holes clogged ).
19.2

GAS FRY-TOP WITH VALVE

The pilot burner does not light
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Igniter defective or not properly connected.
• Igniter or igniter wire defective.
Pilot burner goes out during use
Possible causes:
• Insufficient gas supply pressure.
• Defective gas tap or valve.
• Defective thermocouple or insufficient heating.
• Thermocouple incorrectly connected to gas tap or valve.
• Knob of gas tap or valve not pressed sufficiently.
The main burner does not light ( even though pilot is lit )
Possible causes:
• Insufficient gas supply pressure.
• Blocked tubing or nozzle.
• Defective gas tap or valve.
• Defective burner ( gas outlet holes clogged ).
Heating cannot be adjusted
Possible causes:
• Defective gas valve.
19.3

ELECTRIC FRY-TOP

The appliance does not heat.
Possible causes:
• Temperature thermostat defective.
• Heating elements defective.
• Safety thermostat tripped.
Heating cannot be adjusted
Possible causes:
• Temperature thermostat defective.
19.4

ELECTRIC OVEN

The appliance does not heat.
Possible causes:
• Temperature thermostat defective.
• Heating elements defective.
• Safety thermostat tripped.
Heating cannot be adjusted
Possible causes:
• Temperature thermostat defective.

Publicidad

Tabla de contenido
loading

Tabla de contenido