SETTINGS MENU

1. To access the Settings Menu
2. Navigation :
Sub menus :
Timer "00H":
Maximum value : 24 hours (displays eg : 24H)
Minimum value : 00H = no delay set
To set the timer, scroll through using the Voltage Selection button. After setting the timer, press
Start to start to confirm.
Follow the instructions for the « charge » mode.
The LED's will deactivate until the beginning of the charging cycle. The display will show a count-
down to the start of the charge
If a battery is not connected, the count-down will continue without being displayed. If the
charger does not detect a battery when the count-down has finished, then no charging current
will be supplied to the clamps until a battery has been connected.
In case of polarity reversal, the Gysflash 70-24 HF will continue the count-down, but will not
supply a charging current when the count-down has finished.
DIAG + "13.5"
The « Diag + » feature allows the user to specify the voltage delivered to the battery.
Voltage selection will need to be made each time prior to running the DIAG+ procedure
-
In the settings menu, this option is displayed as the default voltage value "13.5"
-
To scroll up through the voltages available, between 12 and 15V, use the Voltage Select
button. Hold the button to scroll faster.
-
Once you reach 15V, it reverts back to 12V
-
Press "Start/Stop" to confirm selection.
To start using DIAG+ mode, follow the steps of the Diagnostic mode listed on page 14.
Check cables "CAL":
This mode must be used each time the output cables are changed. The Gysflash 70-24 HF is
compatible with cables up to 2x5m in 16mm².
1.
To launch the cables check, select in Settings Menu, and press Start.
2.
The message « SCc » will be displayed.
3.
Put the clamps in short circuit for more than 10 seconds.
Press and hold « START » for 5 seconds.
To scroll through the sub menus, and confirm the sub menu settings.
The sub menus appear in the following order:
Timer "00H"
Cables Testing "CAL"
Restart "LP"
DIAG + "13.5"
To select or modify the values in each sub menu.
NB. For the Timer sub menu: To modify the settings quickly, press and hold.
Press Start to confirm and exit the « settings » menu, in « Cable Test
"CAL" » Start will launch the function.
Charge End "FLt"