The GYSFLASH 32.12 PL uses an advanced 8-step Lithium charging curve that guarantees the optimal performance of your LFP
battery.
1
U
I
Analysis
< 1s
CHARGE
OK
1
Step
: Analysis
Analyses the state of the battery (charge level, polarity inversion, wrong
battery...)
2
Step
: Recovery (
Recovery algorithm following a deep discharge.
3
Step
: Charging (
Fast charging at maximum current allowing to reach 90% of the charge level.
4
Step
: Absorption (13.8 V)
Constant voltage charging to bring the charge level to 98%.
• Estimated charge time :
Charging current
Battery capacity
Charge timing
0% >>> 90%
• Protections :
The GYSFLASH 32.12 PL is equipped with features to protect it against short circuits and polarity reversal. It has an
anti-spark feature which prevents sparks whilst connecting the device to the battery. This charger has double insula-
tion and is safe to use with the battery in situ as it will protect the vehicle's on-board electronics.
The GYSFLASH 32.12 PL is equipped with an integrated temperature sensor that enables it to adapt the charging current according
to the ambient temperature in order to prevent the internal electronics from overheating.
12
GYSFLASH 32.12 PL
2
3
Recovery
Charging
Max 5 min
Max 25 h
-0.5 A /
-1 A /
-7 A /
-15 A /
Lead-acid
15 Ah
60 Ah
60 Ah
100 Ah
2 h
8 h
4 h
6 h
4
5
6
Equalizing Battery System
Absorption
Test
Complement
Max 20 h
3 min
Max 10 h
Step
Charge hold test.
Step
-2 A)
Reduce current charge to reach 100% charge
level.
Step
-30 A)
Balancing the battery cells
Step
Maintain the battery charge level at its maximum
with a maintenance charge every 10 days.
100 Ah
220 Ah
375 Ah
3 h
7 h
12 h
7
Equalization /
Charge retention
balancing
Max 2 h
(maintenance every 10 days)
5
: Test
6
: Complement
7
: Equalization / balancing (14.4 V)
8
: Charge retention (13.8 V)
Lithium
7 Ah
15 Ah
15 Ah
30 Ah
1 h
2 h
1 h
2 h
EN
8
No limit
30 Ah
220 Ah
375 Ah
1h
7 h
12 h