10. Open the drain cock to discharge all of the compressed
air and drain from inside the air tank. If any abnormality is
found in inspection/checking prior to operation, contact
our nearest distributor or Manufacturer Authorized distribu-
tors for inspection/repairing.

OPERATING PROCEDURE

Prior to using the tool.
1. Close the drain cock and turn on the power switch.
2. Once the pressure has increased and operation has
stopped, turn the reducing valve adjusting handle to
adjust to the appropriate working pressure of the nail
driver/pneumatic tool. To adjust the pressure, turn
the reducing valve adjusting handle to left to
decrease the pressure to 2bar lower than the
appropriate value. Then, turn the handle to the
right to adjust the pressure, gradually increasing it.
8
● When adjusting the pressure, be sure to increase it from
lower than the appropriate pressure. If adjustment is
made by decreasing from higher than the appropriate
pressure, there will be error between the indication of
the pressure gauge and actual working pressure.
(Characteristic of the reducing valve.)
● This tool has two reducing valves which can be
connected to high pressure Nailer and a general nail
driver/pneumatic tool. <Reducing valve H> Can
be connected to Powerlite Nailer. <Reducing valve L>
Can be connected to the reguler pressure nailer
(working pressure of 9bar or lower).
WARNING
Be sure to observe the working air pressure of the nailer.
Without adjusting the supply pressure with the reducing
valve, using the nail driver/pneumatic tool could consider-
ably deteriorates its performance, shortens its service life or
damage it, causing danger to you.
● If the nail driver/pneumatic tool is used at inappropriate
pressure (higher than necessary), more air may be
consumed, considerably lowering continuous working
performance of the nail driver/pneumatic tool. Be sure
to use it at appropriate pressure.