AIRFUSION BALI Installation Instructions
PREPARE AND COMPLETE THE ELECTRICAL WIRING --- WIRING DIAGRAM (FIG. 9)
WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A LICENSED
ELECTRICIAN.
NOTE: AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING.
NOTE: IF THERE ARE TWO OR MORE DC CEILING FANS INSTALLED IN THE ONE LOCATION, AN
ISOLATION SWITCH IS REQUIRED FOR EACH CEILING FAN. THIS IS REQUIRED WHEN PROGRAMMING
THE REMOTE AND RECEIVER TO PAIR TOGETHER.
From mains supply to mounting bracket terminal block: (Fig. 9)
Connect the live supply wire to the "L" terminal of the terminal block on the mounting bracket.
1.
Connect the neutral supply wire to "N" terminal of the terminal block on the mounting bracket.
2.
3.
Connect earth wire to the earth terminal of the terminal block on the mounting bracket.
From mounting bracket to receiver and motor : (Fig. 9)
4.
Connect the supply wiring from the mounting bracket to the input of the DC motor driver/receiver.
5.
Connect the output wires of DC motor driver/receiver (from mounting bracket with earth wire ) to the output
of the DC motor driver/receiver (Fig. 9). Connect the output wires of DC motor driver/receiver with earth
wire (from mounting bracket with earth wire ) to the input of the fan motor (Fig. 9)
6.
Connect the output wires of DC motor driver/receiver to the input wires of the fan light kit.
10 | P a g e
ELECTRICAL WIRING DIAGRAM THE FAN
Receiver output wires to
DC motor
DC motor input wiring
connector.
Earth wire
Receiver output wires to
light kit
Light Kit input wiring
connector.
Fig. 9