DESCRIPTION OF LEDS
LED 1
red
Monitors the light barrier for door closing. LED
ON = OK
LED 2
red
Monitors the light barrier for door opening LED
ON = OK
LED 3
yellow
Monitors the emergency stop contact ON=OK
LED 4
green
Indicates signals from key-operated switches,
push-buttons or radio. Single-wing gate/door
opening function ON = signal present.
LED 5
green
Indicates signals from key-operated switches,
push-buttons or radio. Both-wing gate/door
opening function ON = signal present.
LED 6
red
Flashes slowly = OK
Flashes quickly = check all connections to the
motors, capacitor, flashing lamp and remove any
humidity from terminals.
DESCRIPTION OF FUSES
F1
5.0A
Main fuse: Protects the entire control unit and the
motors. Never replace this fuse by one with a
higher rating.
F2
0,5A
Secondary fuse for 24 V output.
F3
2,0A
Secondary fuse for electric lock 12 V output. Please
bear in mind the power requirement of the electric
lock you use.
F4
0,315A
Secondary fuse for logic circuitry: push-buttons,
emergency stop, light barrier, receiver.
TEACHING THE REMOTE CONTROL
Up to 15 remote controls can be programmed on each self-learn
channel. In the case of large installations it is advisable for
organizational reasons, to use an external receiver or a key-operated
switch or a code lock, which should be installed at the entrance.
The radio receiver plugs in on the side and has two small self-learn
buttons.
The radio remote control is licensed by the Post + Telecommunication
Office and costs nothing to operate. It works on the basis of a private
security code that is pre-programmed via computer. Your gate/door
drive can thus only be activated by a correspondingly coded handset.
The range obtained depends on the given local environment. The
receiver element of the motor control has an integrated self-learn
function. It can be set to the handset's pre-programmed code by
pressing the self-learn push-button.
The control unit has two self-learn channels and is therefore able to
open or close one gate/door or both gates/doors simultaneously via
appropriate operation of the handset. Should, for instance, channel 1 (2)
receive the handset's remote control code, only one wing will be
opened. If you teach the remote control on channel 2 (1), you will be
able to open both wings via the appropriate push-button. To memorize
the code all you need do is press the button of your choice on the
handset and keep it depressed while, at the same time, briefly pressing
the self-learn button on the electronic unit with the other hand. Repeat
this procedure for all other transmitters.
DELETION OF REMOTE CONTROL CODE
Press the appropriate self-learn button (1 or 2) on the receiver
control board for approx. 10 seconds until the self-learn LED
extinguishes. The codes previously 'learned' allocated to the given
self-learn button have thus been deleted.
709236B-GB - 05.2004
REPROGRAMMING
For reprogramming purposes, the coding procedure mentioned
above should be repeated for all the remote controls in use and/or
their appropriate operating buttons.
The radio remote control's range varies according to the given local
environment. Keep the push-button on the handset depressed until
such time (approx. 2 seconds) as the gate/door is seen to move.
Your radio remote control is digitally coded, i.e. accidental operation
of the gate/door drive is more or less impossible.
INITIAL OPERATION
Proceed carefully and deliberately. Do not rush the process of
making the basic settings. It may take up to 30 minutes to complete
initial settings. If applicable get help from a second person so that
changes on the control unit can be made more easily (power OFF or
ON).
1. Connect the control unit including the safety inputs.
2. Check the LEDs.
3. Move the gate/door to a half-opened position and engage it, then
press the test button. Both wings must then open. If one wing
closes instead of opening, the terminals on the given wing's
motor have been connected incorrectly and the motor cables for
the relevant motor must be swapped round (see connections).
The cables to which the capacitor is also connected are the ones
that need to be swapped round. They determine the direction in
which the motors run. Then repeat the entire process until both
wings open when they first move. Important, always switch the
power off to do this.
4. If both wings open when they first move once the control unit has
been connected, proceed as follows.
5. Interrupt the power supply to the control unit and reconnect it
after a few seconds. Close both gate/door wings manually and
engage both wings.
6. Adjust all the potentiometers to 30% and make sure that DIP
switch 1 is set to OFF (down).
7. Then use the test button to switch on the control unit and
observe what happens. Close the gate/door again by using the
test button WITHOUT having made any adjustments to the
settings. If the gate/door does not close completely by itself,
release the drive and close it manually after switching off the
control unit.
8. Then adjust the potentiometer to a different (higher) value in line
with the value suggested by practical experience from trial
operation (e.g. increase running time, correct force, wing delay).
Then make a second trial and repeat the procedure above
closing the gate/door first with the test button before making any
further settings.
9. Once all settings have been made, check that the light barriers,
push-buttons, flashing lamp, handset, accessories etc. function
correctly. If you require automatic closing, modify the setting of
the DIP switches and adjust the potentiometer for a pause.
10. Show anyone who has to deal with the gate/door how the
gate/door moves, how the safety functions operate and how the
drive can be actuated manually.
D e c l a r a t i o n o f C o n f o r m i t y
Control unit for ...........................................................................................CB1
is in conformity to the applicable sections of
Standards ...............................................EN300220-3, EN55014, EN61000-3,
............................................................ETS 300 683, EN60555, & EN60335-1
per the provisions & all amendments of
EU Directives .............................................................73/23/EEC, 89/336/EEC
D e c l a r a t i o n o f I n c o r p o r a t i o n
Control unit CB1 meets, when installed and maintained according to all
the manufacturer's instructions, the provisions of EU Directive
89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment specified above
THE CHAMBERLAIN GROUP, INC.
Elmhurst, IL 60126
USA
June, 2003
© Chamberlain GmbH, 2004
and any accessory listed in the manual conforms to the
above Directives and Standards
Barbara P. Kelkhoff
Manager, Reg. Affairs

Publicidad

Tabla de contenido
loading

Tabla de contenido