Descargar Imprimir esta página

SICK WS24-2 Manual De Operación página 12

Ocultar thumbs Ver también para WS24-2:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
6
COMMISSIONING
12
100
10
sensing range
typ. max. sensing range
1
m
10
20
Figure 6: characteristic curve
1
Figure 7: sensing range areas
Table 9: Values for sensing range
WS/WE24-2
1
3
Sensitivity setting
Sensor with potentiometer: open the sensor cover and protective hood, make sure that no
dirt has gotten into the sensor.
The sensitivity is adjusted with the potentiometer (type: without stop). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced. We rec‐
ommend setting the potentiometer to "Maximum".
The sensor is adjusted and ready for operation.
4
Time function setting
WSE24-2xx4x: no time delay, t1 = time delay, t2 = time delay; for -2R: 0 = relay deacti‐
vated, 1 = relay active. Time delay selector switch can be set on the device according to
see table
1.
Time stages: 0.5 ... 10 s can be adjusted.
30
40
50
60
xx3x, xx4x
0 ... 50 m
8008782.Z474 | SICK
Subject to change without notice

Publicidad

loading

Este manual también es adecuado para:

We24-2