Noisy
several operation icons will blink
E0 Code
E2 Code
Can I switch the PROGRESS unit on
immediately after unpacking it?
When switching on the PROGRESS
unit I sense a smell. What should I do?
Can I operate the PROGRESS unit
WITHOUT the extract air hose?
At which intervals should the activated
carbon filter of the PROGRESS unit be
replaced?
- There are heat sources inside the
room.
- Exhaust air hose is not connected or
blocked.
- Temperature setting is too high.
- Air inlet is blocked.
- The ground is not level or not flat
enough
- The sound comes from the flowing of
the refrigerant inside the local air
conditioner
- at a room temperature higher or equal 18°C, Auto mode and cooling mode will
work together.
If the room temperature is equal to or above 18 ° C, the unit can cool in the
automatic mode. At lower temperatures the device will protect the compressor
by automatically switching into ventilation mode.
There is evidence that this error
massage
is
caused
temperature which is too high. It can
also caused by a temporary fault at
the rating between incoming- and
outcoming temperature.
Water tank full
Production-related cause or incorrect
storage of unit at e.g. dusty areas.
Remove the heat sources if possible
Connect or clean the exhaust air hose.
Reset the temperature
Clean the air inlet.
Place the unit on a flat, level ground if
possible
It is normal.
Please turn off the unit and turn in on
to
a
room
after 30 minutes. If this fault is
everlasting, your PROGRESS unit
should be checked by a professional.
Please empty the water tank.
No.
The PROGRESS unit must be placed
upright for at least 24 hours after every
transport. Otherwise the compressor
may be damaged and there is no
capacity.
Odour development can arise on first
use and after a longer period of
non-use by storing in unsuitable areas
(e.g. dusty areas).
Run the unit for ½ a day. The smell will
disappear after a while. In the case of
intensive odour development, air the
room.
Yes, but only in dehumidification
mode.
To achieve temperature adjustments,
surplus coldness must be discharged.
To use the purpose of the filter fully, it
should be replaced every 6 months.
21