System components:
230 V AC Mains voltage
BT
Buffer cylinder (Buffer Tank)
BUS
BUS system EMS 2/EMS plus
CON
User interface EMS 2/EMS plus (Control)
HS...
Heat Source
HS1: heating appliance such as a wall mounted
Greenstar gas condensing boiler
HS2: boiler such as a gas heating boiler
HS3: heat pumps such as an air to water heat pump
IC1
Switching contact for external heat requirement ()
in the associated heating zone,  additional
accessories
MC1
Temperature switch in assigned heating circuit
(optional for heating circuit without mixer; if there is

3.3.4 Connection diagrams with system schematics

The hydraulic diagrams are only schematic illustrations and
provide a non-binding indication of a possible hydraulic circuit.
Heating circuit function
with mixer
Heating
without mixer
Cylinder primary circuit with separate cylinder primary pump
constant
1 unmixed, 3 mixed, 1 cylinder primary circuit with heating appliance
1 unmixed, 3 mixed, 1 cylinder primary circuit with boiler
1 unmixed, 3 mixed, hot water with heat pump
1 unmixed, 2 or more mixed, 2 cylinder primary circuit with heating appliance
Table 5
Wiring diagrams with system examples for the module in combination with heat pump (
1) e.g. downstream of low loss header
MM100
no temperature switch, connect jumper ( Fig. 1
[2], page 91) to terminal MC1)
MM100
module MM100
PC1
Heating pump in the assigned heating circuit
PW1
Cylinder primary pump in assigned cylinder primary
circuit, e.g. after low loss header (coding card on 9
or 10)
PW2
Recirculation pump in the associated hot water
system (code switch on 9 or 10)
T0
Flow temperature sensor on the low loss header or
the buffer cylinder
TC1
Flow temperature sensor in assigned heating circuit
TW1
Cylinder temperature sensor in the assigned
cylinder primary circuit (coding card on 9 or 10)
VC1
Mixing valve actuator in assigned heating circuit
with mixer
1)
Depending on the user interface installed,
maximum 4
▶ Install safety equipment in accordance with applicable
standards and local regulations.
▶ For further information and options, refer to the technical
guides or tender specification.
1)
and DHW circulation pump
Installation | 17
Fig. / Page
 19 / 98
 20 / 99
 21 / 100
 22 / 101
 23 / 102
 24 / 103
 25 / 104
 26 / 105
 27 / 106
) or other heat source (
6 720 813 621 (2014/12)
)