Descargar Imprimir esta página

Rocal D-10 Manual De Instrucciones página 22

Publicidad

Idiomas disponibles

Idiomas disponibles

All combustible items (furniture, Hi-fi, DVD player, TV or carpets) must have a
minimum clearance of 1000 mm from the front of appliance.
1.5. Ventilation. It is important to consider the necessary renewal of air in the
room.
1.5.1. Ventilation with outside air for combustion (C-1). If desired, can be
performed outside air (this can be taken outside the home, garage or basement
ventilated). To perform this outside air intake, plug connection clamp is supplied to
support the rear of the fireplace wall (C-1 A) or the bottom (C-1 B).
1.5.2. Ventilation without outside air for combustion. It should provide for
fresh air intake of a minimum of 80 mm in diameter so that it can not accidentally
be obstructed.
It also must take into account the simultaneous operation with other ventilation
devices and / or heat such as exhaust fans (kitchen, bathroom, etc..), Heat pump,
etc.., In these cases we must compensate with the corresponding extraction
outside air.
1.6. Type of fireplace.
It is a free appliance so must not be covered by any
material.
1.7. Appliance assembly.
1.7.1. Place the wall support. With fireplace will receive the wall support and
corresponding blocks for attachment to the wall. Make sure these are suitable.
The measures of fireplace floor is optional. We consider a length of the bottom of
fireplace to floor 200 mm.
ATTENTION:
This fireplace has an optional foot-platform
. For more information
(see section E)
contact your Rocal distributer.
1.7.2. Plugs characteristics.
RECOMMENDED LOAD WORK
(quality 6.8, concrete 250kg/cm2)
anchorage
Minimum cast (mm)
Pulling resistance
Endurance Kg
H
Kg
10
50
350
450
TECHNICAL DATA
Wall plug size
Screw measure
Drill
Drill min.
Max. depth
Holding Kg. X cm
(mm)
mm
depth
thickness
10 x 80
M8 X 80
10
85
30
150
1.7.3. Place fireplace on the wall support. Once the support is fixed to the wall,
place the chimney above this (C-2) screw (C-3) and level the appliance (C-4).
ATTENTION:
In order to do this you must open the loading door.