ALCOHOL.
Place the load on the central area of the base of the combustion chamber, make
sure the gas log is open and then fire pledge.
2.8. Locking mechanisms. Is necessary to check, after a long period of
shutdown, the exhaust gas connector. Keep the outside air inlet for combustion air
is supplied free of blocking.
2.9. Load door. To open the door, place the handle in the slot of the door (C-24)
and turn down (C-25) opens the door swinging towards us (C-26).
2.10. Cleaning and maintenance of the fireplace.
2.10.1. Cleaning the glass. To clean the glass, do so with the fireplace off,
making sure that the cleaner does not touch the metal parts of the door or ceramic
board, due to the aggressiveness of these products can begin a process of
corrosion of the fireplace. To open the door to use the tool provided for this
purpose.
2.10.2. Fire Grate (C-27). The fireplace is supplied with two bars located in the
center of the combustion chamber.
2.10.3. Ash removal. Empty inside the chimney when it is completely off, making
sure that the ashes do not contain hot coals and in any case may deposit them in
a metal bucket until total extinction.
2.10.3. Interior cleaning of the appliance and sweeping the chimney. It is
important to keep waste connector and chimney flue exhaust gas. These get dirty
more or less depending on the fuel used, more or less slow progress of
combustion, etc.. It is necessary to clean the chimney at least once per season.
To access the flue from inside the chimney is necessary to remove the baffle
plate. It is mandatory that a specialist periodically review these items.
2.10.4. Paint. The exothermic paint lining the inside and outside the appliance
supporting up 600 ° C temperature and shows a slight characteristic odor that
disappears early on.
It is also possible that after some time, the paint inside the fireplace wears off due
to the liquid corrosion, fuel or other reasons. In this case, it will be necessary to
wear the rusty zones off and repaint them again.
(Use only the spray "Rocal spray pint 600ºC BLACK – No gris antracita).
2.11. In case of a chimney fire. In case of a chimney fire fully close both the air
controls and ensure that all flammable items are at least 1000 mm away from any
part of the fireplace. The house must be evacuated and the Fire Bridge called.
Special care must be taken when children or elderly people are around.
2.12. Operating in adverse weather. It is possible that in certain weather
conditions the fireplace may not operate correctly, insufficient flue draft may cause
puffs of smoke from the air inlets, close both the controls to shut down the
appliance. If these phenomena persist, consult your installer.
2.13. Modification of the appliance. Any modification must be authorized in
writing by Rocal Manufacturers SA. It is also compulsory to use the spare pieces
recommended by Rocal Manufacturers SA.