Features Of The Delivery Pipes - HPP EL Serie Instrucciones Para El Ensamblaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73

FEATURES OF THE DELIVERY PIPES

In consideration of the high pressures employed, the delivery pipe must be designed and built with
materials suitable for such working conditions.
The same applies for any accessories installed.
When designing the system take into consideration the pressure drops along the line.
To limit the pulsating loads, typical of piston pumps, install a suitable damper or flexible pipe
(minimum 1.5 m long) between the pressure regulator and pump connection.
The accessories listed below must be used on the pump's circuit. Each accessory shall be correctly
dimensioned/rated and meet the requirements of current standards:
• Gauge
• Safety valve
• Pressure regulator valve, manual or automatic
• Antipulsation damper
38
90° CURVES
"T" CONNECTIONS
OVERTURNED "U" CURVES
DIAMETER
REDUCTION
NEGATIVE HEAD
TANK
TANK
SAFETY VALVE
TANK WALL
FILTER
YES
ACCUMULATOR
PRESSURE GAUGE
SAFETY VALVE
PUMP HEAD
FILTER
BYPASS RECIRCULATION DURING SUCTION
NO
ACCUMULATOR
PRESSURE GAUGE
PUMP HEAD
BY-PASS LINE
VALVE
OUT
BY-PASS
VALVE
OUT
BY-PASS
Fig. 08