Outputs configuration
Assign the channels at P&H PRO Injector Driver according to the outputs
assigned at the ECU map.
The driver supports (although is not recommended) utilizing distinct impedance
injectors at the same driver, just set the Peak and Hold current for each injector
individually.
7.2 Safety protections
The PRO Injector Driver protections allows ECU alert or even module shutoff.
Select one or all alerts, as desired.
ECU safety Alert: Will use CAN to send an alert to the ECU. The ECU will
act (screen alert only, engine shut off) accordinly with the ECU Alert Settings,
if activated and configurated.
Shut driver off: Shuts off the PRO Injector Driver.
IMPORTANT
When selecting Shut driver off the Driver will shut off
when detect failure, this will shut off the engine by fuel
cut off.
NOTE
This protections are only for the P&H PRO Injector Driver.