Idiomas disponibles

Anleitung_TH_SH_3_10_SPK8__ 07.09.12 09:47 Seite 10
GB
Damaged switches have to be replaced by a
customer service workshop. Never use tools with
a switch that cannot be turned on and off.
20. Important.
- For your own safety you must only use the
accessories and additional units listed in the
operating instructions or recommended or
specified by the manufacturer. The use of
mounted tools or accessories other than those
recommended in the operating instructions or
catalog may place your personal safety at risk.
21. Repairs may only be carried out by a
qualified electrician
- This electric tool complies with the pertinent
safety regulations. Repair work must only be
carried out by a trained electrician, otherwise the
equipment may cause accidents.
22. Connect up a vacuum extraction system
- If there are provisions for connecting up a
vacuum extraction system, make sure that such a
system is fitted and in use.
2. Layout (Fig. 1)
1. Handle
2. Drill bit guide hole
3. Opening for emptying grinding dust
4. On/Off switch
5. Power cable
3. Items supplied
Open the packaging and take out the equipment
n
with care.
Remove the packaging material and any
n
packaging and/or transportation braces (if
present).
Check to see if all the items are supplied.
n
Inspect the equipment and accessories for
n
transport damage.
If possible, keep the packaging until the end of
n
the guarantee period.
IMPORTANT
The equipment and packaging material are not
toys. Do not let children play with plastic bags,
plastic sheets and small parts. There is a risk of
choking and suffocating!
Drill bit grinder
n
Original Operating Instructions
n
10
4. Intended use
The drill bit grinder is designed for grinding drill bits
for working with metal (HSS bits) with diameters of 3-
10 mm.
The equipment must be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user/operator and not the manufacturer
will be liable for any damage or injuries of any kind
resulting from such misuse.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
equipment is used in commercial, trade or industrial
businesses or for equivalent purposes.

5. Technical data

Mains voltage:
230 V ~ 50 Hz
Power consumption:
Idling speed:
1500 min
Drill bit diameter:
3-10 mm
Protection class:
Weight:
S3 50%: Intermittent mode, no start-up, no braking
(cycle duration 2 minutes). In intermittent mode, the
percentage load factor (50%) is always quoted so
that the heat generated during this period can be
dissipated during breaks in operation by convective
cooling. Intermittent mode consists of the on time and
the cooling breaks, known as the duty cycle. The
period of consideration is 2 minutes. 50% load factor
means that the electric tool can be operated for one
minute at the rated performance, followed by a
cooling phase of one minute.
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745.
L pA sound pressure level
76 dB(A)
K pA uncertainty
L WA sound power level
89 dB(A)
K WA uncertainty
Wear ear-muffs.
The impact of noise can cause damage to hearing.
55 W
-1
II / ®
2,1 kg
3 dB
3 dB