Technical Data - Hilti SF BT 22­A Manual Del Usuario

Ocultar thumbs Ver también para SF BT 22­A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
3.5
Li­ion battery display
The charge status of the Li-ion battery and malfunctions of the power tool are indicated by the display on
the Li­ion battery. The charge status of the Li­ion battery is displayed after pressing one of the two battery
release buttons.
Status
4 LEDs light.
3 LEDs light.
2 LEDs light.
1 LED lights.
1 LED blinks, the power tool is ready for use.
1 LED blinks, the power tool is not ready for use.
4 LEDs blink, the power tool is not ready for use.
Battery charge status cannot be displayed while the control switch is pressed and for up to 5 seconds
after releasing the control switch.
If the battery display LEDs blink, please observe the instructions given in the Troubleshooting section.
3.6
Items supplied
Electric drill, operating instructions.
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
4

Technical data

4.1
Drill
Rated voltage
Weight in accordance with EPTA Procedure 01 including B22⁄8.0
battery
Torque
Keyless chuck clamping range
4.2
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise emission values determined in accordance with EN 62841
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Sound (power) level (L
WA
Uncertainty for the sound power level (K
16
English
)
pA
)
pA
)
)
WA
Meaning
Charge status: 75 % to 100 %
Charge status: 50 % to 75 %
Charge status: 25 % to 50 %
Charge status: 10 % to 25 %
Charge status: < 10 %
The battery has overheated or is completely dis-
charged.
The power tool is overloaded or has overheated.
21.6 V
2.6 kg
≤ 9 Nm
1 mm ... 10 mm
SF BT 22­A
71 dB(A)
3 dB(A)
82 dB(A)
3 dB(A)