Operation mode (page 2&3)
Depending on the setting of this hexadecimal rotary switch, a relay module channel will function as follows:
Start/stop timer : Operating the push button will switch on the relay. After the set time has elapsed, the relay turns off. Operat-
0
ing the push button when the relay is switched on will immediately switch off the relay.
Staircase lighting timer : Operating the push button will switch on the relay. After the set time has elapsed, the relay will turns
1
off. Operating the push button when the relay is switched on will restart the timer.
Non-restartable timer : Operating the push button will switch on the relay. After the set time has elapsed, the relay turns off.
2
Operating the push button when the relay is switched on has no effect.
Switch-off delay : The relay will be switched on as long as the push button is operated. Releasing the push button will start the
3
timer. After the set time has elapsed, the relay turns off.
Switch-on delay : Operating the push button will start the switch-on delay. The relay will only be switched on after this switch-
4
on delay has elapsed. Operating the push button when the switch-on delay is running will immediately switch off the switch-on
delay. Operating the push button when the relay is on will immediately switch off the relay.
5
Start timer with push button release : The relay switches on during the set time by releasing the push button.
Blink timer : Operating the push button will make the relay blink. After the set time has elapsed, the relay turns off. Operating
6
the push button while the relay is blinking will immediately switch off the relay.
2-way timer : A short press will switch on the relay during the set time 'Time1'. A long press will switch on the relay during the
7 - F
set time 'Time2'. Operating the push button when the relay is on will immediately switch off the relay.
Remarks: If the rotating switch of the time setting is set on '0', the relay module will always operate in moment control
regardless of the set operation mode. If the rotating switch of the time setting is set on 'F', the relay module will operate in
on/off mode.