Batteries - Nilfisk-Advance Adphibian Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BATTERIES

If your machine shipped with batteries installed do the following:
Check that the batteries are connected to the machine (17).
Turn ON the Key Switch (A) and check the Battery Indicator (D2). If the gauge is completely fi lled, the batteries are ready for use. If the
gauge is less than full, the batteries should be charged before use. See the "Charging The Batteries" section.
IMPORTANT!: YOUR MACHINE HAS AN ONBOARD BATTERY CHARGER, REFER TO THE OEM PRODUCT MANUAL FOR
INSTRUCTIONS REGARDING SETTING THE CHARGER FOR BATTERY TYPE (SEE CHART).
If your machine shipped without batteries installed do the following:
Consult your Authorized Nilfi sk-Advance dealer for recommended batteries.
Install the batteries by following the instructions below.
DO NOT install two 12 volt batteries in your machine. This affects the stability of the machine.
IMPORTANT!: YOUR MACHINE HAS AN ONBOARD BATTERY CHARGER, REFER TO THE OEM PRODUCT MANUAL FOR
INSTRUCTIONS REGARDING SETTING THE CHARGER FOR BATTERY TYPE (SEE CHART).
AH/Rate
MFG
255
Discover
251
US
180
DEKA(gel)
201 / 195
US / Trojan
235
US / Trojan
WARNING!
Use extreme caution when working with batteries. Sulfuric acid in batteries can
cause severe injury if allowed to contact the skin or eyes. Explosive hydrogen gas
is vented from the batteries through openings in the battery caps. This gas can be
ignited by any electrical arc, spark or fl ame. Do not install any lead-acid battery in a
sealed container or enclosure. Hydrogen gas from overcharging must be allowed
to escape.
When Servicing Batteries...
Remove all jewelry
Do not smoke
Wear safety glasses, rubber gloves and a rubber apron
Work in a well-ventilated area
Do not allow tools to touch more than one battery terminal at a time
ALWAYS disconnect the negative (ground) cable fi rst when replacing batteries to
prevent sparks.
ALWAYS connect the negative cable last when installing batteries.
CAUTION!
Electrical components in this machine can be severely damaged if the batteries are
not installed and connected properly. Nilfi sk-Advance, a qualifi ed electrician, or the
battery manufacturer should install batteries.
1
Remove the batteries from their shipping crate and carefully inspect them for cracks or other damage. If damage is evident, contact the carrier
that delivered them or the battery manufacturer to fi le a damage claim.
2
Turn the Master Key Switch (A) OFF and remove the key.
3
Tip the recovery tank to the side, locked position. Remove the battery cables from inside the battery compartment.
4
Your machine comes from the factory with enough battery cables to install four 6 volt batteries. Carefully lift the batteries into the battery
compartment and arrange them exactly as shown in FIGURE 1. Secure the batteries as close to the back of the machine as possible.
5
Install the battery cables as shown. Position the cables so the battery caps can be easily removed for battery service.
6
Carefully tighten the nut in each battery terminal until the terminal will not turn. Do not over-tighten the terminals, or they will be very diffi cult to
remove for future service.
7
Coat the terminals with spray-on battery terminal coating (available at most auto parts stores).
8
Put one of the black rubber boots over each of the terminals and connect the Battery Pack Connector (17).
Algorithm
43
72
6
11 / 3
11 / 3
FIGURE 1
Adphibian
/ AX 651 Combi EDS - 56041711 - A-11
ENGLISH / A-11

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Ax 651 combi eds

Tabla de contenido