Ordering Components; Ordering Extra Components; Recycling The Compressor - Prebena PKT Fillmaster 400 Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Fault Condition
Fault Condition
F
Operating power is falling.
G
Intermediate pressure: the safety valve is
thrown out.
H
The compressor is getting burned.
I
High oil consumption.

Ordering Components

You can order components from the producer in addition (See p. 25). Use only original components
PREBENA or ones having admittance by the company of PREBENA for using with these compressors.

Ordering Extra Components

All Types
Code Number
Z 200.40
00205801
KT-3500-S
KT-1000-SY
You can find other components on the

Recycling the Compressor

LOOK OUT!
There exists a danger for the environment by recycling by environmentally inexpedient way.
Clean the computer before recycling.
Observe requirements of working legislative directions for recycling oil.
24
Possible Causes
Piston rings are too large.
Leakage of the pipeline.
Pollution of the receiving filter.
A clearance between the piston and
the cylinder of the 3
large.
Intermediate pressure is too high, the
valves are leaky.
No air for cooling.
The environmental temperature is too
high.
Sucking / pressure valve is leaky.
Pistons, piston rings and / or cylinders
are worn out.
The receiving filter is polluted.
Superheating the computer.
Components
The special oil of PREBENA
The adapter for filling cartridges of the compressed air of KT-1000
The cartridges of the compressed air of KT-3500 in a metallic box for transporting, in duplicate.
The cartridges of the compressed air of KT-1000 in a systainer, 5 copies.
www.prebena.de
In no circumstances, throw the compressor or its components into usual dustbins. If you want
to recycle the compressor, send it to the company of PREBENA. The company of PREBENA
will recycle the compressor properly. You can find the contact data in p. 25.
Remedy
Check again the piston rings or replace them.
Take the department of work with clients (See p. 25).
Turn a screw joint.
Clean or replace the receiving filter.
Check again a clearance between the piston and cylinder.
stage is too
Take the department of work with clients (See p. 25).
rd
Check the valves.
Take the department of work with clients (See p. 25).
Check again machines laying.
The maximal environmental temperature is +40°C
Check the valves and replace them if it is necessary.
Take the department of work with clients (See p. 25).
Replace the spares.
Take the department of work with clients (See p. 25).
Clean or replace the receiving filter.
Increase the power of cooling.

Publicidad

Tabla de contenido
loading

Tabla de contenido