Parker EO2 – FORM F3 Manual De Instrucciones página 46

Tabla de contenido

Publicidad

Trouble
8. Roughness of the
sealing
surface
too
large
9. RESET - button
flashes slowly
10. RESET - button
flashes fast; START
button cannot be
operated
Cause
Forming pin dirty
Forming pin worn, no lubricant uses
Temperature too high
Oil level too low
No tooling in the machine
Forming pin disconnects from bayonet fixing
- 46 -
Solution
Clean forming pin
Lubricate tube inside and outside.
Exchange forming pin
Leave
cooling
the
approx. 5 min
Check the oil level; if necessary
refill hydraulic oil
Insert a tool into the machine
Insert the forming pin correctly;
and through turn right the forming
pin, in order to lock the forming
pin in the bayonet fixing