Auger Maintenance; Maintaining The Auger; Important - Toro 58630 Manual Del Operador

Ocultar thumbs Ver también para 58630:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Auger Maintenance

Maintaining the Auger

Service Interval: Every 50 hours
Gear case grease capacity: 118 mL (4 fl oz)
1.
Add grease only if the level of the grease is
below top of the gears.

Important:

Do not overfill the gear case.
2.
Keep all screws, nuts, and bolts tight.
3.
For cold-weather operation, store the machine
in a cool environment.
Important:
Transferring the machine from
a warm place to a cold place can cause
condensation, which may damage the
machine.
4.
If the auger performance decreases, carefully
inspect the cutting edge of the blade for signs of
wear and/or damage.
If the blades show any of these signs, replace
the blades.