15. Specifications
Weight w/ batteries............................. 1.4 kg
Weight w/o batteries........................... 1 kg
Dimensions
Length ............................................. 28.5cm
Width............................................... 11.0cm
Height.............................................. 56.0cm
Power Source
4 C-size batteries, 1.5V Alkaline (ANSI/NEDA 14A, IEC
LR14) or 1.2V NiMH or NiCad rechargeable batteries
Power Rating: 6V, 550mA
Operating Environment
Temperature.................................... 20°C to 50°C
Humidity .......................................... 5% to 95% RH
Storage Temperature.......................... -20°C to 60°C
Standard Frequencies
Sonde............................... 512Hz, 640Hz, 874Hz, 33kHz
Active Line Trace ............................ 128Hz, 8kHz, 33kHz
Passive Line Trace ......................... 60Hz, 50Hz
16. Icon Legend
Default Settings
The default settings for the locator are:
Depth units = Meter and centimeter
Volume = 1 (one setting above mute)
Backlight = Auto
.
Standard Equipment
.
Scout Locator
.
Markers and Mast Holder
.
2 Operator's Manuals: US + Europe
.
4 C-cell batteries (Alkaline)
Video PAL
.
Optional Equipment
.
Additional Pole/sonde Markers
.
NaviTrack Transmitter
.
Inductive Clamp
.
Battery Sonde
Float