10. Switchable pulse frequency, 8 kHz / 16 kHz; default setting: 8 kHz
8 kHz: pulse frequency for two-pole motors, e.g. inrunners.
16 kHz: pulse frequency for motors with more than two poles, e.g. outrunners.
11. Low-voltage cut-off mode; default setting: soft
Soft: reduced power
Hard: complete cut-off
Programming
1. Switch the transmitter on and move the throttle stick fully forward. Connect the flight battery to
the speed controller (ESC).
2. After five seconds you will hear the first audio sequence of programming mode. If you leave
the throttle stick at the full-throttle position, the controller generates various audio sequences
indicating the user-variable parameters - see table below.
3. The audio sequence for each individual parameter is repeated four times. If you wish to chan-
ge a particular parameter, move the throttle stick to the Stop position within the period of the
four repetitions. After this the controller emits an audio sequence according to the set battery
type (see "Using the speed controller for the first time").
Note: every time you change a parameter, disconnect the speed controller from the battery
for about five seconds; this causes the unit to store the new setting.
You can only change one parameter during each programming process.
Audio sequences in programming mode
Audio sequences
1
Full-throttle / Stop position
--, --, --, --
2
Brake
-*, -*, -*, -*
3
Battery type
~, ~, ~, ~
~~, ~~, ~~, ~~
4
Low-voltage cut-off
*--, *--, *--, *--
*---, *---, *---, *---
*----, *----, *----, *----
5
Reset to default settings
-, -, -, -
6
Timing
-, -, -, -
--, --, --, --
---, ---, ---, ---
7
Start-up / Power-on mode
vv, vv, vv, vv
v, v, v, v
vvv, vvv, vvv, vvv
© robbe Modellsport
All manuals and user guides at all-guides.com
Operating instructions
Nano-Vector ARF Power Set
8
9
10
11
Safety notes
- Take care to maintain correct polarity in all wiring.
- It is essential to avoid short-circuits.
- Install and protect the speed controller in such a way that it cannot come into contact with gre-
ase, oil or water.
- Provide adequate air circulation for cooling.
- Keep well clear of the rotational plane of the propeller when the battery is connected - injury
hazard.

Controller functions

Guarantee
Naturally we guarantee this speed controller for the statutory period of 24 months. If you believe
you have a valid claim under guarantee, please contact your dealer in the first instance, as he
Brake on / off
is responsible for processing guarantee claims. During the guarantee period we will correct any
operating deficiencies, production defects and material faults which arise, at no charge to you. We
NiMH / NC
will not entertain any claims beyond these terms, e.g. consequent damage.
LiPo
The unit must be returned to us carriage-paid; it will also be returned to you carriage-paid. We will
not accept goods sent to us without pre-paid carriage.
Low: 2.8 V / 50%
We accept no liability for transit damage and the loss of your shipment; we therefore recommend
Medium : 3.0 V / 60%
that you take out suitable insurance to cover these risks.
High: 3.2 V / 60%
Send the unit to the Service Centre responsible for the country in which you live.
Reset
The following conditions must be fulfilled if we are to process your guarantee claim:
• Send proof of purchase (till receipt) with your shipment.
Automatic (7 - 30°)
• The unit must have been operated in accordance with the operating instructions.
Low (7 - 22°)
• The unit must have been operated with the recommended power sources and genuine robbe
High (23 - 30°)
accessories.
• The unit must not exhibit damage due to damp, unauthorised intervention, reverse polarity,
Ultra-soft
overload conditions or mechanical damage.
Soft
• Please include a concise description of the fault or defect, as this will help us identify the pro-
Normal
blem.
6
Helicopter mode
-*-, -*-, -*-, -*-
-**-, -**-, -**-, -**-
-***-, -***-, -***-, -***-
Motor direction
W, W, W, W
Pulse frequency
//, //, //, //
\\, \\, \\, \\
Low-voltage / Cut-off mode
---", ---", ---", ---"
"---, "---, "---, "---
Keep to the correct sequence when switching on: always switch the transmitter on
first, followed by the receiver. Reverse the sequence when switching off.
Do not exceed the values stated in the Specification.
No.
2580
Speed governor mode off
Soft-start, 5 sec. delay
Soft-start, 15 sec. delay
Right / Left
8 kHz
16 kHz
Reduced power
Full cut-off