Adjusting: (see figure T2)
– Loosen all Allen screws 28 with the Allen key
30 provided.
– Turn the fence 9 until the angle gauge is flush
over the complete length.
– Retighten the screws again.
Aligning the Angle Indicator (Horizontally)
(see figure U)
– Bring the machine into the transport posi-
tion.
– Turn the saw table 17 to the 0° detent 16.
The lever 14 must be felt to engage in the de-
tent.
Checking:
The angle indicator 15 must be in alignment
with the 0° mark of the scale 10.
Adjusting:
– Loosen the fastening screw of the angle indi-
cator with the supplied Phillips screwdriver
30 and align the angle indicator alongside the
0° mark.
– Retighten the screw again.
Transport
Before transporting the power tool, the follow-
ing steps must be carried out:
– Loosen the locking screw 26 if tightened.
Pull the tool arm completely to the front and
tighten the locking screw again.
– Bring the machine into the transport posi-
tion.
– Remove all accessories that cannot be
mounted firmly to the power tool.
If possible, place unused saw blades in an
enclosed container for transport.
– For lifting or transporting, hold the power
tool by the recessed grips 36 on the side of
the saw table 17.
The power tool should always be carried by
two persons in order to avoid back injuries.
When transporting the power tool, use only
the transport devices and never use the
protective devices.
1 609 929 X03 | (29/7/10)

Maintenance and Service

Maintenance and Cleaning

Before any work on the machine itself, pull
the mains plug.
If the machine should fail despite the care taken
in manufacturing and testing procedures, repair
should be carried out by an after-sales service
centre for Bosch power tools.
In all correspondence and spare parts order,
please always include the 10-digit article
number given on the type plate of the machine.
Cleaning
For safe and proper working, always keep the
power tool and its ventilation slots clean.
The retracting blade guard must always be able
to move freely and retract automatically. There-
fore, always keep the area around the retracting
blade guard clean.
Remove dust and chips after each working pro-
cedure by blowing out with compressed air or
with a brush.
Accessories
Quick-action clamp . . . . . . . . . . 2 608 040 205
Insert plate. . . . . . . . . . . . . . . . . 2 607 960 019
Dust bag. . . . . . . . . . . . . . . . . . . 2 605 411 204
Angle adapter
for dust bag . . . . . . . . . . . . . . . . 2 600 499 071
Extension bars . . . . . . . . . . . . . . 2 607 001 911
Saw blades for wood and plate materials, pan-
els and strips/mouldings
Saw blade 254 x 30 mm,
60 teeth . . . . . . . . . . . . . . . . . . . 2 608 640 438