56 | MERCURE 200 | Commissioning
4.6

Electrical connection

DANGER – Risk of electric shock if connec-
tions are not or not correctly grounded or
from incorrect mains voltage.
Incorrect phase, neutral and ground connec-
tions can cause electric shocks, heart failure
and fatalities!
Work on electrical installations or equip-
ment is only to be performed by qualified
electricians or trained personnel under the
guidance and supervision of an electrician.
Even minor work on the electrical system
is only to be performed by appropriately
trained and qualified personnel.
The MERCURE 200 is only to be connected
to the power supply if the mains voltage
available corresponds to the rated voltage
given on the rating plate.
Check the grounding before connecting
the MERCURE 200.
Use the type of power cord specified for
the country concerned.
Only connect to an appropriate approved
grounding-type socket.
In the event of operating problems, switch
off immediately by way of the On/Off
switch, disconnect the power cord and
consult the "Faults" section of the operat-
ing instructions.(cap. 12).
i The MERCURE 200 must be connected to the power
supply by way of protective fuses or an automatic
circuit breaker or a single-pole disconnector with at
least 3 mm contact gap in accordance with European
standards. The customer is responsible for providing
fuse protection for the mains connection.
i The power cord included in the scope of delivery of
the machine is provided with a standardized connec-
tor in line with European standards.
Fig. 28:
Power cord connection - Back of MERCURE 200
1 On/off switch
2 Grounding-type socket.
3 Power cord
4 Connection for angular width gauge*
*Depending on version, special accessory in some cases
|
1 695 109 017
2019-01-07
4.5

Checking the direction of rotation

1. Check that the MERCURE 200 is correctly connected
to the mains power supply.
2. Switch on the MERCURE 200 with the On/Off
switch.
3. Confirm by pressing <OK>.
4. Close the wheel protection cap.
 The shaft rotates.
i If the shaft does not turn, press the <START> key
5. Check the direction of rotation of the shaft.
i The correct direction of rotation is indicated by an
adhesive on the right side of the MERCURE 200
(chap.1.2.1).
i If the direction of rotation is incorrect, the
MERCURE 200 comes to an immediate stop and dis-
plays the error message ERR 3 (see section 12).
4.7

Calibration of MERCURE 200

! Calibration must be performed after initial commis-
sioning.
1. Flange calibration;
2. Electronic Vernier caliper;
3. MERCURE 200 calibration;
4. Perform reference measurement.
i Calibration is described in Section 13.3.