46 9. Balancing A Wheel; 46 9.1 Balancing Programs - WERTHER INTERNATIONAL MERCURE 200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

9.
Balancing a wheel
WARNING – Incorrectly balanced wheels
Risk of injury due to change in handling char-
acteristics of vehicle.
MERCURE 200 must be positioned on a
flat surface and must be firmly bolted to
the floor.
Specified flange must be mounted on
clean and grease-free shaft.
Use the specified accessories (cone,
spacer rings).
Rim must contact flange accurately, re-
move any dirt.
Perform a check measurement after apply-
ing balancing weights.
¶ MERCURE 200 is to be switched on at the on/off
switch.
 The software version appears for a short time.
i In the following description the audio is activated.
To balance the wheel:
$ Select the balancing program;
$ Entering of rim data;
$ Measuring of imbalance;
$ Fastening of the balancing weights.
i To rule out balancing errors, the handle of the elec-
tronic vernier caliper must be held properly when
calibrating the rim data.
Fig. 38:
Werther International S.p.A.
Balancing a wheel | MERCURE 200 | 61
9.1
Balancing programs
Symbol
Button
Standard program for spring-clip weights.
Recommended for Steel rims.
Alu1: Standard program for adhesive weights
Recommended for Alloy rims.
Alu2: Non-standard program for hidden adhesive
weights
Recommended for Alloy rims.
Alu3: Non-standard program
spring-clip weights inside /
outside concealed adhesive weights
Recommended for Alloy rims.
Alu4: Standard program
spring-clip weights inside /
loutside adhesive weights
Recommended for Alloy rims.
Alu5: Standard program
Inside adhesive weights /
spring-clip weights outside
Recommended for Alloy rims.
Static balancing for spring-clip weights.
Standard program
Recommended for Iron rims.
Static balancing for adhesive weights
Standard program
Recommended for Alloy rims.
Static balancing for hidden adhesive weights
Standard program
Recommended for Alloy rims.
Pax1: Standard program for adhesive weights
(Pax rim)
Pax2: Non-standard program for hidden adhesive
weights
(Pax rim)
Symbol
Key
Standard program for spring-clip weights.
Recommended for Steel rims.
Alu1: Standard program for adhesive weights
Recommended for Alloy rims.
Static balancing for spring-clip weights.
Standard program
Recommended for Iron rims.
Static balancing for adhesive weights
Standard program
Recommended for Alloy rims.
Static balancing for hidden adhesive weights
Standard program
Recommended for Alloy rims.
Pay attention to the current settings for attachment of the adhe-
1)
sive weight (refer to Section 9.7)!
The weight must be raised slightly if the adhesive weight can-
2)
not be attached in the vicinity of the outer edge of the rim (rim
flange) on account of the design of the rim
" Lighting of the LEDs indicates the positions of the
balancing planes for each balancing program selected.
en
|
1 695 109 017
2019-01-07

Publicidad

Tabla de contenido
loading

Tabla de contenido